Induction motors are optimal for uni-directional continuous operation such as a conveyor system.Optimal for uni-directional continuous operationConform to safety standards and global power supply voltages
| Power | 0.03333 hp |
|---|---|
| Rated Speed | 1300 [200 VAC, 50 Hz] 1600 [60 Hz] |
| Rated Torque | 0.16 N·m [60 Hz] 0.19 N·m [50 Hz] |
| Frame Size | 80 mm |
| Voltage | Three-Phase 200/220/230 VAC |
| Current | 0.21 A [200/220 VAC, 60 Hz] 0.22 A [230 VAC, 60 Hz] 0.23 A [200 VAC, 50 Hz] |
| Electrical Phase | Three-Phase 200/220/230 VAC |
| Frequency | 60 50 |
| Shaft Type | Round Shaft (No Gearhead) |
| Shaft Diameter | 8 mm |
| Ip Rating | IP54 (Excluding the Installation Surface of the Round Shaft Type) |
| product line | Oriental Motor® |
| motor type | Induction |
| frame size(imperial) | 3.15 in |
| output power | 25 W (1/30 HP) |
| voltage (vac) | Three-Phase 200/220/230 VAC |
| frequency (hz) | 60 50 |
| shaft/gear type | Round Shaft (No Gearhead) |
| output shaft | Metric |
| output shaft diameter | 8 mm |
| type | Terminal Box |
| electromagnetic brake | Not Equipped |
| rated torque(imperial) | 1.38 lb-in [60 Hz] 1.63 lb-in [50 Hz] |
| rated speed (rpm) | 1300 [200 VAC, 50 Hz] 1600 [60 Hz] |
| permissible overhung load | 10 mm from Shaft End = 90 N 20 mm from Shaft End = 140 N |
| permissible overhung load(imperial) | 0.39 in. from Shaft End = 20 lb 0.79 in. from Shaft End = 31 lb |
| permissible thrust load | Avoid thrust load as much as possible. If thrust load is unavoidable, keep it to half or less of the motor mass. |
| rohs compliant | Yes |
| safety standards | UL CSA CCC EN CE |
| ce marking | Low Voltage Directives |
| insulation resistance | 100 MΩ or more when 500 VDC megger is applied between the windings and the frame after rated motor operation under normal ambient temperature and humidity. |
| dielectric strength | Sufficient to withstand 1.5 kV at 50 Hz or 60 Hz applied between the windings and the frame for 1 minute after rated motor operation under normal ambient temperature and humidity. |
| temperature rise | Temperature rise of windings are 126ºF (70ºC) or less measured by the resistance change method after rated motor operation with connection to an aluminum heat radiation plate [5.31 x 5.31 in. (135 x 135 mm), Thickness: 0.2 in. (5 mm)] |
| insulation class | Class B (266ºF [130ºC]) |
| overheat protection | Built-in thermal protector (Automatic return type). Operating temperature, open: 266°F ± 9°F (130°C ± 5°C) close: 185°F ± 36°F (85°C ± 20°C) |
| ambient temperature range | Three-phase 200 VAC: 14ºF ~ 122ºF (-10ºC ~ 50ºC) (nonfreezing) Other voltage: 14ºF ~ 104ºF (-10ºC ~ 40ºC) (nonfreezing) |
| ambient humidity | 85% maximum (noncondensing) |
| degree of protection | IP54 (excluding the installation surface of the round shaft type) |
| Unidad | piece |
| Cantidad mínima | 1 |
| Incremento de cantidad | 1 |
| Fabricante | Oriental Motor |
| Vendor SKU | 4IK25A-SW2T |
| Lead Time | Estimated Ship: 10/22/2024 |