The CCT series DIN rail signal conditioners are designed to accept a broad range of input signals, such as ac and dc voltage and current, frequency, temperature (thermocouple and RTD), and process transducers, and provide standard process outputs of either 0/4 to 20 mA, or 0 to 10 Vdc. The CCT series features a modern housing design, that is easily mounted on standard DIN rails. Connections are safely and securely made, with input and output connections on the opposite sides of the module. Internal Design The CCT series is designed using an internal plug-in three module system that provides flexibility in selecting and changing the power supply, input signal and output signal. The units are supplied with 110 Vac power standard, Consult sales for 220 Vac, and 24 Vdc power. Isolation The three internal modules in each signal conditioner (signal input, signal output and power supply) are isolated up to 2 kVeff. Outputs Each CCT series signal conditioner is available with current and voltage output (only one may be used at a time). Available output types include 4 to 20 mA or 0 to 20 mA (jumper-selectable) and 0 to 10 Vdc. Standard outputs are linear and proportional to the signal input. Thermocouple input modules feature special circuitry to linearize the output to the actual temperature, and not to the non-linear signal produced by thermocouple sensors.
| Input Type | Voltage |
|---|---|
| Isolation | 2000 Vrms |
| brand | OMEGA Engineering |
| accuracy | ± 0.2 % |
| approvals | CE, UL |
| approvals note | Enclosure: UL 94 V-1, Terminal Housing: UL 94-2 |
| bandwidth | 1.5 Hz (-3 dB) |
| current measurement range | N/A |
| enclosure ratings | IP20, IP40 |
| frequency measurement range | N/A |
| height | 75 mm |
| length | 110 mm |
| materials | Polycarbonate, RAL 7032 |
| mounting | DIN Rail 46277 and EN 50022 |
| number of inputs | 1 |
| operating temperature, max | 60 °C |
| operating temperature, min | -10 °C |
| output detail | 15 Vdc @ 5 mA source or 100 mA sink with 24 Vdc external supply Output Ranges: 1 pulse/hr to 10,000 pulses/sec full scale; jumper select and poteniometer adjustment |
| output ripple | ≤0.5% |
| output signal | Voltage |
| output value | Process |
| power consumption | max 1.5 VA |
| pulse rates | 50% or fixed 100 ms |
| response time | ≤250 ms |
| serial number | Break Protection: Jumper selectable, upscale (>20 mA) or downscale (<4 mA) |
| storage temperature, max | 80 °C |
| storage temperature, min | -30 °C |
| supply power note | 110 Vac (standard); 220 Vac or 24 Vdc (optional) (±10% tolerance on all power supplies) |
| supply power type | AC |
| supply voltage | 110 Vac |
| temperature coefficient | ≤0.015%/°C |
| temperature measurement range | N/A |
| voltage measurement range | 0 to 0.1 Vdc, 0 to 1 Vdc, 0 to 10 Vdc, 0 to 100 Vdc, 0 to 650 Vdc |
| voltage output range | 15 Vdc |
| weight | 270 g |
| width | 45 mm |
| wire gauge | 14 AWG |
| Unidad | piece |
| Cantidad mínima | 1 |
| Incremento de cantidad | 1 |
| Fabricante | Omega |
| Vendor SKU | CCT-55-V |
| Lead Time | If not in stock: 6 weeks |