Line Volt Mechanical Tstat, Close on Rise, -30 Degrees to 90 Degrees F, SPST, 120V/240V/277V AC
| Switch Action | Close on Rise |
|---|---|
| Voltage | 120V/240V/277V AC |
| Sensor Type | Hydraulic Capillary Bulb (Copper) |
| Differential | 3.5 Degrees F |
| Thermostat Control Range | -30 to 90 deg F |
| Switch Type | SPST |
| Color | Polished |
| Width | 2-1/8 in |
| Height | 4-1/2 in |
| Depth | 2-1/8 in |
| Thermostat Programmable | No |
| Temp. Sensitivity | 3 deg F |
| Remote Sensing Capability | Yes |
| Enclosure Type | Stainless Steel |
| Includes | Mounting Hardware |
| Pilot Duty Contacts (VA) | 125 VA |
| Remote Sensing Bulb Included | Yes |
| Thermostat Heating/Cooling | Cooling |
| Control Range | -30 to 90 deg F |
| Resistive Amps @ 208VAC | 22 A |
| Thermostat Switch Type | SPST |
| Full Load Amps @ 120VAC | 16 A |
| Item | Line Volt Mechanical Tstat |
| Contact Rating Resistive @ 240V | 22 A |
| Inductive Amps @ 240V | 8 A |
| Contact Rating Resistive @ 120V | 22 A |
| Sensing Bulb Dia. | 3/16 in |
| Thermostat Voltage | 24 to 600 V AC |
| Standards | cULus |
| Locked Rotor Amps @ 240V | 48 A |
| Full Load Amps @ 240VAC | 8 A |
| Capillary Length | 60 in |
| Sensing Bulb Length | 5 in |
| Inductive Amps @ 120V | 16 A |
| Inductive Amps @ 208V | 9.2 A |
| Number of Switches | 1 |
| Thermostat Item | Line Voltage Mechanical Thermostat |
| Locked Rotor Amps @ 120V | 96 A |
| Mounting | Vertical or Horizontal |
| Thermostat Type | Indoor Single-Stage Controls |
| Application | Refrigeration |
| Contact Rating Resistive @ 277V | 22 A |
| For Use With | Refrigeration Device Or Motor Driven Ventilator |
| Temperature Limiting | No |
| Features | 430 Stainless Steel and Copper Alloys |
| Control Type | Exposed Dial |
| Dehumidification Control | No |
| Phase | 1 |
| Maximum Operating Temperature | 110 deg F |
| Maximum Control Temperature | 90 deg F |
| Contact Rating | 120/240/277V AC |
| Frequency | 50 Hz, 60 Hz |
| Shape | Rectangle |
| Overall Depth | 2-1/4 in |
| Minimum Control Temperature | -30 deg F |
| Bulb Length | 5 in |
| Temperature Sensitivity | +/-3 deg F |
| Number of Heating Stages | 0 |
| Stages | 1C |
| Pilot Duty Rating | 125 VA @ 24 to 600V AC |
| Overall Height | 5-3/4 in |
| Temperature Scale | Fahrenheit |
| Temperature Control Range | -30 to 90 deg F |
| Bulb Diameter | 1/4 in |
| Number of Poles | 1 |
| Minimum Operating Temperature | -30 deg F |
| Number of Cooling Stages | 1 |
| Electrical Connection Type | Hardwired |
| Enclosure NEMA Rating | 1 |
| Resistive Amps @ 208V AC | 22 A |
| Contact Type | Snap Action |
| Capillary Length/Bulb Diameter | 5 ft Capillary, 5 in x 1/4 in Bulb |
| Compatible System Type | Attic Fans, Fan Coil Units |
| Changeover Type | Automatic |
| Switch Type/Action | SPST on Rise |
| Temperature Differential | 3 Degrees F |
| Enclosure Finish | Polished |
| Operating Temperature Range | -30 to 110 deg F |
| Sensor Location | Remote |
| Differential Type | Fixed |
| Overall Width | 2-1/4 in |
| Mounting Direction | Vertical |
| Enclosure Material | Stainless Steel |
| Enclosure Color | Gray |
| Country of Origin (subject to change) | China |
| Package Quantity | 1 |