The DRSL-RTD Series RTD input DIN rail signal conditioners provide a competitive choice in terms of both price and technology for interfacing RTD inputs to SCADA systems or PLC equipment. The DRSL-RTD and DRSL-RTD-ISO can be used for signal conversion of 2, 3 or 4-wire Pt100 RTD inputs into unipolar analog signals. The DRSL-RTD-ISO isolated model offers 3-way isolation between input, output and supply and provides surge suppression and protects control systems from transients and noise. Low power consumption facilitates DIN rail mounting without the need for any air gap. Easy configuration of more than 1000 factory calibrated measurement ranges is done via DIP-switches. The unit operates over a wide temperature range from -25 to 70°C (-13 to 158°F).
| Input Type | RTD |
|---|---|
| brand | OMEGA Engineering |
| accuracy | ± 0.1 % |
| accuracy detail | Better than 0.2°C or ±0.1% of selected range |
| approvals | CE, UL, RoHS |
| calibration temperature, max | 28 °C |
| calibration temperature, min | 20 °C |
| emc immunity note | NAMUR NE 21, A Criterion, Burst: <±1% of span (span = selected input range) |
| emc standard | NAMUR NE 21 |
| electrical output | 4 to 20 mA |
| enclosure ratings | IP20 |
| height | 113 mm |
| input range note | Sensor Current, RTD: <150 µA;Sensor Cable Specifications: 50 Ωper wire or 50 nF;Effect of Sensor Cable Resistance (3 or 4-wire RTD): <0.002 Ω/Ω;Broken Sensor Detection: >800 Ω;Shorted Sensor Detection: <18 Ω |
| installation | Pollution degree 2 and measurement/overvoltage category II |
| length | 115 mm |
| load resistance | Current Output : 21 mA/600Ω /12.6V max;Voltage Output:>10 kΩ min |
| mounting | DIN Rail 35 mm Standard, EN 60715 |
| noise calibration | >60 dB |
| number of inputs | 1 |
| operating temperature, max | 70 °C |
| operating temperature, min | -25 °C |
| output detail | Current: Range Limits(NAMUR NE43 Out of Range):Below 3.8 mA or above 20.5 mA for 4 to 20 mA output; 0 mA or above 20.5 mA for 0 to 20 mA output Sensor Error Detection(Dip Switch Selectable for Enable or None): Below 3.5 mA or above 23 mA for 4 to 20 mA output; 0 mA or above 23 mA for 0 to 20 mA output Incorrect DIP-Switch Setting Identification: Below 3.5 mA or above 23 mA for 4 to 20 mA output; 0 mA or above 23 mA for 0 to 20 mA output Output Error Level: DIP switch selectable for upscale or downscale. Voltage: Range Limits (Out of Range):Range ±2.5% Sensor Error Detection (Dip Switch Selectable for Enableor None): 0V or selected range + 10% Incorrect DIP-Switch Setting Identification: 0V Output Error Level: DIP switch selectable for upscale or downscale |
| output signal | Current, Voltage |
| output value | Process |
| power consumption | 0.7 W, Internal - 0.65 W |
| relative humidity | 0 to 95% RH (non-condensing) |
| response time | < 30 ms |
| response time note | Response Time (0 to 90%, 100 to 10%): <30 ms/300 ms (selectable, provides either fast response or signal dampening as needed) |
| screw terminal torque | 0.5 Nm |
| stability | Load Stability: ≤0.01% of span/100 Ω |
| storage temperature, max | 85 °C |
| storage temperature, min | -40 °C |
| supply power note | 16.8 to 31.2 Vdc via connectors |
| supply power type | DC |
| supply voltage | 16.8 to 31.2 Vdc |
| temperature coefficient | ≤±0.02°C/°C |
| voltage output range | 0 to 10 Vdc |
| weight | 70 g |
| width | 6.1 mm |
| wire gauge | 26 to 13 AWG |
| Unidad | piece |
| Cantidad mínima | 1 |
| Incremento de cantidad | 1 |
| Fabricante | Omega |
| Vendor SKU | DRSL-RTD |
| Lead Time | If not in stock: 5 Days |