Item | Power Monitor and Condition Monitoring Kit |
---|---|
Voltage - Batteries | 3.7 V |
Promotion Restriction | Not eligible for promotion |
Voltage | Full cycle RMS (20 ms at 50 Hz, 16.7 ms at 60 HZ) |
IEC 61010-1 | IEC mains input: Overvoltage Category II, Pollution Degree 2 || Voltage terminals: Overvoltage Category IV, Pollution Degree 2 |
Bandwidth (-3 dB) | 42.5 Hz to 3.5 kHz |
Frequency range | 2412 MHz to 2462 MHz |
Input impedance | 10 MΩ each phase to neutral |
IP rating | IEC 60529:IP50, in connected condition with protection caps in place |
Storage altitude | 12,000 m (39,000 ft) |
Dimensions (WxHxD 3540 FC with power supply attached | 19.8 cmx 16.7 x 9 cm (7.8 x 6.6 x 4.0 in) |
Sampling frequency | 10.24 kHz at 50/60Hz, synchronized to mains frequency |
International | IEC 61326-1: Industrial |
Operating altitude | 2000 m (6,500 ft) (up to 4,000 m derate to 1000 V CAT II/600 V CAT III/300 V CAT IV) |
Output power | <100 mW |
Battery power | Li-ion 3.7 V, 9.25 Wh, customer-replaceable |
Averaging interval | 1 s |
Tamper protection | Kensington lock |
Input signal frequency | Mains 50/60 Hz (42.5 to 69 Hz) |
Power consumption | Maximum 50 VA (max. 15 VA when powered using IEC 60320 input) |
Resolution | 16-bit synchronous sampling |
Memory size | Typical 1 offline logging session of 1 week with 1 second intervals. The number of possible logging sessions and logging period depends on user requirements. |
Power | 200 ms |
Mains frequency | 50/60 Hz±15 % |
Vibration | MIL-T-28800E, Type 3, Class III, Style B |
Standby power | <0.3 W only when powered using IEC 60320 input |
Supported modes | Direct connection and connection to infrastructure |
Scaling | 1:1, variable, 1:1 and variable |
Current sensor output voltage Clamp | 500 mVrms / 50 mVrms; CF 2.8 |
Operating humidity | <10°C (<50°F) non condensing || +10°C to +30°C (+50°F to +86°F) ≤95 % || +30°C to +40°C (+86°F to +104°F) ≤75 % || +40°C to +45°C (+104°F to +113°F) ≤45 % |
Voltage range | Nominal 100 V to 500 V (85 V min to 550 V max) using safety plug input |
Efficiency | ≥68.2 % (in accordance with energy efficiency regulations) |
Data storage | Internal flash memory (not user replaceable) |
Maximum input voltage | 1000 Vrms (1700 Vpk) phase to neutral |
Number of inputs | 3, mode selected automatically for attached sensor, 4 (3 phases and neutral) |
Wiring configurations | 1-Φ, 1-Φ IT, Split-phase, 3-Φ wye, 3-Φ wye IT, 3-Φ wye balanced, 3-Φ delta, 3-Φ Aron/Blondel (2-element delta), 3-Φ delta open leg, 3-Φ high leg delta, 3-Φ delta balanced. Currents only (load studies) |
Operating Temperature | 0°C to +45°C |
On-battery runtime | Up to 4 hr (up to 5.5 hr in energy saving mode) |
Storage temperature | <20°C to +60°C (-4°C to +140°F), with battery: -20°C to +50°C (-4°F to +122°F) |
Measured parameters | Voltage, current, frequency, THD V, THD A, power, power factor, fundamental power, DPF |
Charging time | <6 hr |
Color LCD display | 4.3-inch active matrix color TFT, 480 pixels x 272 pixels, resistive touch panel |
Mains power | Nominal 100 V to 240 V (85 V min to 265 V max) using IEC 60320 C7 input |
Bandwidth | 42.5 Hz to 3.5 kHz |
USB-A | Firmware updates, max. supply current: 120 mA |
Total harmonic distortion | THD for voltage and current is calculated on 25 harmonics |
Dimensions (WxHxD 3540 FC | 19.8 x 16.7 x 5.5 cm (7.8 x 6.6 x 2.2 in) |
Current sensor output voltage Rogowski coil | 150 mVrms/15 mVrms at 50 Hz, 180 mVrms/18 mVrms at 60 Hz; CF 4; all at nominal probe range |
Current | Half cycle RMS (10 ms at 50 Hz, 8.3 ms at 60 Hz) |
Dimensions (WxHxD Detachable power supply | 13.0 x 13.0 x 4.5 cm (5.1 x 5.1 x 1.8 in) |
USA (FCC) | 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. |
Security | WPA2-AES with pre-shared key |
Package Quantity | 1 |