Item | Automatic Standby Generator |
---|---|
Fuel Type | Natural Gas/Propane |
Generator Fuel Type | Liquid Propane/Natural Gas |
Phase | Three |
Transfer Switch Included | No |
Amps | 87 |
Rated Voltage | 120/208V AC |
Generator Voltage | 120V AC/208V AC |
Engine Cooling | Liquid |
Standby Power Rating | 25kW LP / 25kW NG |
Carbon Monoxide (CO) Sensor | No |
CARB Compliant | No |
Battery Requirements | 26R, 525 CCA |
Power Factor | 0.8 |
Run Time Hour Meter | Yes |
Includes | Isochronous Electric Governor, Smart Battery Charger, Two Line LCD Multilingual Digital Evolution Controller |
Min. Gas Pressure @ Generator (In WC) | 5 to 14 |
Main Circuit Breaker | 100 A |
Engine Block Heater | Optional |
Automatic Volts Regulation | Yes |
Fuel Tank Capacity | Not Applicable |
NG Consumption @ Half Load | 297 cu ft/hr |
12VDC Battery Charger | Yes |
Repeat of Exercise Cycle | 7 day |
Enclosure Material | Aluminum |
Width | 29 in |
Over Speed Shutdown | No |
Low Oil Pressure Alarm | Yes |
High Temp. Alarm | Yes |
Length | 62-3/16 in |
Height | 29-11/16 in |
Standards | CA/MA, CSA Certified, EGSA, EPA, NEMA, UL 2200 |
Over Crank Protection | Yes |
Low Coolant Level Alarm | yes |
Engine (Block Heater) | Optional |
Fuel NPT Pipe Connection Sz. | 3/4 in |
Generator Mfr. Warranty Details | 5 yr |
Hz | 60 Hz |
Engine RPM | 3,600 RPM |
kVA Rating | 31 kVA |
kW | 25 LP/25 GN |
Battery Included | No |
Engine Size | 1.5 L |
LP Consumption @ Half Load | 3.3 gph |
Fault Indicator Lights | Yes |
Length (Straight Wireway) | 62-15/16 in |
Weight | 777 lb |
Frame Material | Steel |
Rated Watts | 25,000 |
Color | Grey |
Engine Brand | Generac |
Apparent Power Rating | 31 kVA |
Carbon Monoxide Protection | No Carbon Monoxide Detection |
Battery CCA Rating | 525 CCA |
Run Time @ Full Load - Diesel | Not Applicable |
Run Time @ 1/2 Load - Diesel | Not Applicable |
Safety Features | Low Oil Shutdown, Automatic Voltage Regulator (AVR), Common External Fault Capability, Failure to Transfer Protection, Governor Failure Protection, High Temperature Shutdown, Incorrect Wiring Protection, Internal Fault Protection, Low Battery Protection, Over Speed Shutdown, Overcrank Protection, Safety Fused |
Overall Height | 29-11/16 in |
Noise Level | 72 dBA |
Starter Type | 12V |
Exercise Cycle Interval | 7 day |
Service Rated Transfer Switch | No |
Wi-Fi Equipped | Yes |
Natural Gas (NG) Consumption @ 1/2 Load | 140 cfh |
Rated Current @ 120V AC - Diesel | Not Applicable |
Rated Current @ 120V AC - Propane (LPG) | 87 A |
Exercise Cycle Duration | 90 sec |
Running Wattage - Diesel | Not Applicable |
Running Wattage - Natural Gas (NG) | 25 kW |
Rated Current @ 240V AC - Diesel | Not Applicable |
Manufacturer Warranty | 5 yr |
Propane (LPG) Consumption @ Full Load | 2.1 gph |
12V DC Battery Charger | Yes |
Overall Length | 62-3/16 in |
Engine Oil Capacity | 4 qt |
Transfer Switch Current Rating | Not Applicable |
Includes Battery | No |
Rated Current @ 120V AC - Natural Gas (NG) | 87 A |
Fuel NPT Pipe Connection Size | 3/4 in |
Minimum Fuel Pressure - Natural Gas (NG) | 5 in wc |
Rated Current @ 240V AC - Natural Gas (NG) | Not Applicable |
Rated Frequency | 60 Hz |
Overall Width | 28-7/8 in |
Engine Type | 4-Cycle |
Maximum Fuel Pressure - Natural Gas (NG) | 14 in wc |
Propane (LPG) Consumption @ 1/2 Load | 1.2 gph |
Engine Speed | 3,600 RPM |
Natural Gas (NG) Consumption @ Full Load | 221 cfh |
Battery Group Number | Group 26 |
Running Wattage - Propane (LPG) | 25 kW |
Package Quantity | 1 |