Automatic Standby Generator, Three Phase, 30kW LP/30kW NG, Liquid Cooled
| Item |
Automatic Standby Generator |
| Fuel Type |
Natural Gas/Propane |
| Generator Fuel Type |
Liquid Propane/Natural Gas |
| Phase |
Three |
| Transfer Switch Included |
No |
| Amps |
90 |
| Rated Voltage |
120/240V AC |
| Generator Voltage |
120V AC/240V AC |
| Engine Cooling |
Liquid |
| Standby Power Rating |
30kW, 30kW LP NG |
| Carbon Monoxide (CO) Sensor |
No |
| CARB Compliant |
No |
| Automatic Volts Regulation |
Yes |
| Battery Included |
No |
| Fuel Tank Capacity |
Not Applicable |
| Includes |
Isochronous Electric Governor, Smart Battery Charger, Two Line LCD Multilingual Digital Evolution Controller |
| Main Circuit Breaker |
Yes |
| Over Speed Shutdown |
No |
| kW |
30 LP/30 NG |
| Power Factor |
0.8 |
| High Temp. Alarm |
Yes |
| Hz |
60 Hz |
| Generator Mfr. Warranty Details |
5 yr |
| Min. Gas Pressure @ Generator (In WC) |
5 to 14 |
| Fuel NPT Pipe Connection Sz. |
3/4 in |
| Enclosure Material |
Aluminum |
| Low Coolant Level Alarm |
yes |
| Low Oil Pressure Alarm |
Yes |
| Height |
29-11/16 in |
| Width |
29 in |
| Standards |
CA/MA, CSA Certified, EGSA, EPA, NEMA, UL 2200 |
| Over Crank Protection |
Yes |
| kVA Rating |
38 kVA |
| Engine Block Heater |
Optional |
| Fault Indicator Lights |
Yes |
| LP Consumption @ Half Load |
3.5 gph |
| Engine Size |
1.5 L |
| Battery Requirements |
26R, 525 CCA |
| 12VDC Battery Charger |
Yes |
| Engine RPM |
3,600 RPM |
| Length |
62-3/16 in |
| Engine (Block Heater) |
Optional |
| Repeat of Exercise Cycle |
7 day |
| Run Time Hour Meter |
Yes |
| NG Consumption @ Half Load |
320 cu ft/hr |
| Length (Straight Wireway) |
62-15/16 in |
| Color |
Grey |
| Weight |
807 lb |
| Rated Watts |
30,000 |
| Frame Material |
Aluminum |
| Noise Level |
73 dBA |
| Transfer Switch Current Rating |
Not Applicable |
| Running Wattage - Diesel |
Not Applicable |
| Starter Type |
12V |
| Apparent Power Rating |
38 kVA |
| Rated Current @ 240V AC - Diesel |
Not Applicable |
| Minimum Fuel Pressure - Natural Gas (NG) |
5 in wc |
| Safety Features |
Low Oil Shutdown, Automatic Voltage Regulator (AVR), Common External Fault Capability, Failure to Transfer Protection, Governor Failure Protection, High Temperature Shutdown, Incorrect Wiring Protection, Internal Fault Protection, Low Battery Protection, Over Speed Shutdown, Overcrank Protection, Safety Fused |
| Propane (LPG) Consumption @ 1/2 Load |
128 gph |
| Engine Brand |
Generac |
| Battery Group Number |
Group 26 |
| Includes Battery |
No |
| Overall Width |
28-7/8 in |
| Overall Height |
29-11/16 in |
| Run Time @ 1/2 Load - Diesel |
Not Applicable |
| Rated Current @ 120V AC - Natural Gas (NG) |
90 A |
| Exercise Cycle Duration |
90 sec |
| 12V DC Battery Charger |
Yes |
| Wi-Fi Equipped |
Yes |
| Maximum Fuel Pressure - Natural Gas (NG) |
14 in wc |
| Engine Oil Capacity |
4 qt |
| Exercise Cycle Interval |
7 day |
| Propane (LPG) Consumption @ Full Load |
197 gph |
| Engine Type |
4-Cycle |
| Overall Length |
62-3/16 in |
| Fuel NPT Pipe Connection Size |
3/4 in |
| Rated Current @ 120V AC - Propane (LPG) |
90 A |
| Service Rated Transfer Switch |
No |
| Rated Frequency |
60 Hz |
| Rated Current @ 120V AC - Diesel |
Not Applicable |
| Running Wattage - Natural Gas (NG) |
30 kW |
| Natural Gas (NG) Consumption @ 1/2 Load |
320 cfh |
| Rated Current @ 240V AC - Propane (LPG) |
90 A |
| Natural Gas (NG) Consumption @ Full Load |
492 cfh |
| Carbon Monoxide Protection |
No Carbon Monoxide Detection |
| Manufacturer Warranty |
5 yr |
| Running Wattage - Propane (LPG) |
30 kW |
| Engine Speed |
3,600 RPM |
| Run Time @ Full Load - Diesel |
Not Applicable |
| Rated Current @ 240V AC - Natural Gas (NG) |
90 A |
| Battery CCA Rating |
525 CCA |
| Package Quantity |
1 |