| Item - Motion Sensing and Dimming | Occupancy Sensor |
|---|---|
| Communication Method - Motion Sensing and Dimming | Hard Wired |
| Sensing Technology | Passive Infrared |
| Installation Location - Motion Sensor | Wall Switch Box |
| Coverage at Suggested Mounting Height | 2,100 sq ft |
| Operating Voltage - Motion Sensing and Dimming | 120/230/277 V AC |
| Color - Motion Sensing and Dimming | Light Almond |
| Time Delay Adjustment Method - Motion Sensor | Adaptive, Adjustable |
| Time Delay - Motion Sensor | 30 sec to 30 min |
| Standards | cUL/US Certified, FCC Approved, Title 24, Part 6 |
| Item | Occupancy Sensor |
| Communication Method | Hard Wired |
| Color | Light Almond |
| Sensor Type | Occupancy |
| Time Delay | 30s-30m |
| Coverage Angle - Motion Sensor | 180 deg |
| Description/Special Features | Beep Warn - Unit Beeps 3 Times After Delayed-Off Time Expires, then Waits 10 Seconds Before Turning Lights Off, Convenient Dual Pushbuttons Provide Manual-On/Off Light Switching of Each Load At Any Time, Daylight Harvesting Light Sensor Measures the Ambient Light in the Room When it First Detects Motion, Exclusive Leviton H.I.S. Circuitry, Exclusive Walk-Through, False Detection Circuitry, Ground Connection Required. Gangable With Other Devices, Horizontal Field-Of-View May be Adjusted Between 180 Degrees and 60 Degrees Arc by Using Integral Blinders Located on Either Side of the Lens. No Mask-Ing Tape Required, Light Sensor Adjustable Ambient Light Override Ranges From Approximately 2Fc (20 Lux) to 500+Fc (5000+ Lux), Low-Profile Design Eliminates Obtrusive "Scanning-Device" Look, Manual-On/Auto-Off Mode for Installations Where Manual-on Switching is Required But Auto-Off Switching is Still Desired for CEC Title T24 Energy Savings, ODSOD-ID Classroom Mode, ODSOD-ID Conference Room Mode, Presentation Mode, Segmented Fresnel Lens Provides Optimum Sensitivity and Performance. Designed With An Extensive "Minor Motion" Area Where Even Slight Body Movements will be Detected, to Comply With CEC Title 24, Red Led Indicator Light Flashes When PIR Sensor Detects Motion to Verify Detection is Active, Unit Fits in Standard Single-Gang Wallbox and Replaces Two Single-Pole Wall Switches, Vandal Resistant PIR Lens |
| Voltage | 120/230/277 VAC |
| Max. Capacity @ 277VAC | 2700V (Primary Relay Fluorescent) |
| Includes | Photocell |
| Max. Capacity @ 120VAC | 1200V (Primary Relay Fluorescent), 800V (Secondary Relay Fluorescent), 800W (Incandescent) |
| Lighting Technology | Incandescent |
| Includes Wall Plate | Wall Plate Not Included |
| Manufacturer Warranty | 5 yr |
| Load Rating @ 480V AC | Not Applicable |
| Minimum Time Delay | 30 sec |
| Number of Gangs | 1 |
| Load Rating @ 120V AC | 1,200VA (Primary Relay Fluorescent), 800V (Secondary Relay Fluorescent), 800W (Incandescent) |
| Installation Location | Wall |
| Overall Width | 1-3/4 in |
| Time Delay Adjustment Method | Adaptive |
| Series | Decora |
| Maximum Time Delay | 30 min |
| Overall Height | 4.06 in |
| Rated Frequency | 50/60 Hz |
| Dimming Method | No Dimming |
| Compatible with Series | Switching Only |
| Minimum Operating Temperature | 32 deg F |
| Sensor Operation | Occupancy, Photocell, Vacancy |
| Number of Buttons | 2 |
| Load Rating @ 277V AC | 2,700V (Primary Relay Fluorescent) |
| Maximum Coverage Area | 2,100 sq ft |
| Fan Rated | Yes |
| Overall Depth | 1.83 in |
| Maximum Operating Temperature | 122 deg F |
| Neutral Required | No |
| Includes Motion Sensor | Yes |
| Dimming Type | No Dimming |
| Nightlight | No |
| Includes Dimming Switch | Dimming Switch Not Included |
| Coverage Type | Small Motion |
| Coverage Angle | 180 deg |
| Maximum Detection Distance | 40 ft |
| Relay Type | Dual Relay |
| Load Rating | Primary Relay Fluorescent: 1200VA @ 120V 2700VA @ 277V Incandescent: 800W @ 120V - Secondary Relay Fluorescent: 800VA @ 120V 1200VA @ 277V Incandescent: 800W @ 120V |
| Frequency | 50/60Hz |
| Power Consumption | 120V - 110mW, 277V - 270mW |
| Wiring | Primary Relay No. 16 AWG leads: Line-Black, Load-Blue, Ground-Green - Secondary Relay N0. 18 AWG isolated contact leads: (2) Red |
| Neutral Wire Connection | Not Required |
| Coverage (Sq.Ft.) | 2100 |
| Sensor Technology | Passive Infrared |
| Operating Temperature | 32° to 122°F (0° to 50°C) |
| Mounting Type | Wall Switch |
| Product Type | Occupancy Sensor |
| Mounting | Wall Switch |
| Grade | Commercial |
| Relative Humidity | 20% to 90% non-condensing |
| Pattern | 180° |
| Listings | cUL/US Certified, can be used to comply with Title 24, Part 6 occupancy sensing requirements, FCC Compliant |
| Storage Temperature Range | 14° to 185°F |
| Application | Classrooms, Multimedia Rooms, Daylight Harvesting, Conference Rooms, Day Care Centers, Offices, Lounges, Bi-Level or A/B Switching |
| Size | Height 4.06" (103.2mm), Width 1.75" (44.4mm), Depth 1.83"(47mm), Install Depth 1.35"(34.4mm), Install Height 2.60"(66.2mm) |
| Switch Type | Single-Pole, Dual Relay |
| Package Quantity | 1 |