| Item | Pendant control station XAC-A - 6 pushbu |
|---|---|
| Standards | IEC 60947-5-1, UL 508, IEC 60204-32, CSA C22.2 No 14 |
| Enclosure Material | Polypropylene |
| Maximum Resistance Across Terminals | 25 MOhm |
| [Uimp] Rated Impulse Withstand Voltage | 6 kV IEC 60947-1 |
| Ip Degree of Protection | IP65 conforming to IEC 60529 |
| Contact Operation | slow-break |
| Electrical Circuit Type | control circuit |
| Protective Treatment | TH |
| Mechanical Interlocking | with mechanical interlocking between pairs |
| Product Compatibility | ZB2BE101 for each direction, XENT1192 for emergency stop |
| Device Short Name | XACA |
| Ik Degree of Protection | IK08 EN 50102 |
| Shock Resistance | 100 gn IEC 60068-2-27 |
| Terminal Identifier | NC, NO |
| Control Station Composition | 6 push-buttons + 1 emergency stop |
| Cable Entry | rubber sleeve with stepped entry 8-26 mm |
| Vibration Resistance | 15 gn 10-500 Hz)IEC 60068-2-6 |
| Connections - Terminals | screw clamp terminals, 1 x 0.5...1 x 2.5 mm² without cable end, screw clamp terminals, 1 x 0.5...2 x 1.5 mm² with cable end |
| Enclosure Type | complete ready for use |
| Control Station Type | double insulated |
| [Ui] Rated Insulation Voltage | emergency stop contact 400 V 3)IEC 60947-1, 600 V 3) |
| Control Button Type | first push-button 1 NO raise, slow, second push-button 1 NO lower, slow, fourth push-button 1 NO left, slow, third push-button 1 NO right, slow, stop push-button Ø 40 mm 3 NC latching, fifth push-button 1 NO forward slow, sixth push-button 1 NO reverse, slow |
| [Ithe] Conventional Enclosed Thermal Current | 10 A |
| Control Station Colour | yellow |
| Overvoltage Category | class II IEC 61140 |
| Product or Component Type | control station |
| Control Station Application | control of single speed hoist motor |
| Range of Product | Harmony XAC |
| Terminals Description Iso N°2 | (21-22)NC, (11-12)NC, (31-32)NC |
| Mechanical Durability | 1,000,000 cycle |
| Contact Code Designation | A600 AC-15, Ue = 240 V, Ie = 3 A IEC 60947-5-1 appendix A, A600 AC-15, Ue = 600 V, Ie = 1.2 A IEC 60947-5-1 appendix A, Q600 DC-13, Ue = 250 V, Ie = 0.27 A IEC 60947-5-1 appendix A, Q600 DC-13, Ue = 600 V, Ie = 0.1 A IEC 60947-5-1 appendix A |
| Rated Operational Power In W | 40 W DC-13 1000000 cycles 60 cyc/mn 120 V 0.5 inductive IEC 60947-5-1 appendix C, 48 W DC-13 1000000 cycles 60 cyc/mn 48 V 0.5 inductive IEC 60947-5-1 appendix C, 65 W DC-13 1000000 cycles 60 cyc/mn 24 V 0.5 inductive IEC 60947-5-1 appendix C |
| Ambient Air Temperature For Operation | -25-70°C |
| Ambient Air Temperature For Storage | -40-70°C |
| Terminals Description Iso N°1 | NO |
| Operating Force | 10-10 N push-button, 14-14 N emergency stop |
| Short-Circuit Protection | 10 A (fuse protection cartridge gG) |
| Product Certifications | CCC || GOST |
| Package Quantity | 1 |