TeSys Deca, relé de sobrecarga térmica, 80 a 104 A, clase 10A.
| Item |
THERMAL OVERLOAD 80-104 A CL10A |
| Depth |
132 mm |
| Standards |
EN/IEC 60947-4-1, EN/IEC 60947-5-1, UL 60947-4-1, UL 60947-5-1, CSA C22.2 No 60947-4-1, CSA C22.2 No 60947-5-1, GB/T 14048.4, GB/T 14048.5, EN 50495 |
| Ambient Air Temperature For Operation |
-20-60°C without derating IEC 60947-4-1 |
| Auxiliary Contact Composition |
1 NO + 1 NC |
| Product or Component Type |
differential thermal overload relay |
| Control Type |
Red push-button stop, Blue push-button reset |
| Dielectric Strength |
2.2 kV 50 Hz IEC 60947-1 |
| Temperature Compensation |
-20-60°C |
| Range |
TeSys |
| Network Frequency |
0...400 Hz |
| Device Short Name |
LRD |
| Network Type |
AC, DC |
| Tightening Torque |
control circuit 1.7 N.m screw clamp terminals, power circuit 9 N.m screw clamp terminals |
| [Ue] Rated Operational Voltage |
1000 V AC 0...400 Hz power circuit IEC 60947-4-1 |
| Connections - Terminals |
power circuit screw clamp terminals 1 4-35 mm² flexible with cable end, control circuit screw clamp terminals 2 1-2.5 mm² flexible without cable end, control circuit screw clamp terminals 2 1-2.5 mm² flexible with cable end, control circuit screw clamp terminals 2 1-2.5 mm² solid without cable end, power circuit screw clamp terminals 1 4-50 mm² flexible without cable end, power circuit screw clamp terminals 1 4-50 mm² solid without cable end |
| Tripping Threshold |
1.14 +/- 0.06 Ir IEC 60947-4-1 |
| Associated Fuse Rating |
4 A gG for signalling circuit, 4 A BS for signalling circuit |
| [Uimp] Rated Impulse Withstand Voltage |
6 kV IEC 60947-1 |
| Thermal Protection Adjustment Range |
80 to 104 A |
| Permissible Current |
0.06 A 440 V DC-13 signalling circuit, 0.12 A 600 V AC-15 signalling circuit |
| Climatic Withstand |
IACS E10 |
| Mechanical Robustness |
vibrations6 Gn IEC 60068-2-6, shocks15 Gn for 11 ms IEC 60068-2-7 |
| Product Compatibility |
LC1D115, LC1D150 |
| Ip Degree of Protection |
IP20 conforming to IEC 60529 |
| Ambient Air Temperature For Storage |
-60-70°C |
| [Ui] Rated Insulation Voltage |
power circuit 1000 V IEC 60947-4-1, power circuit 600 V CSA, power circuit 600 V UL |
| Relay Application |
motor protection |
| Thermal Overload Class |
class 10A IEC 60947-4-1 |
| Product Name |
Deca, TeSys, TeSys LRD |
| [Ith] Conventional Free Air Thermal Current |
5 A (signalling circuit) |
| Mounting Support |
plate, with specific accessories, rail, with specific accessories, under contactor |
| Flame Retardance |
V1 conforming to UL 94 |
| Package Quantity |
1 |