| Operator | Switch |
|---|---|
| NEMA Size | Not Applicable |
| Enclosure NEMA Rating | No Enclosure |
| Depth | 96 mm |
| Frame Size | S0 |
| Height | 97 mm |
| Overload Relay Amp Setting | 27 to 32 A |
| Amps AC | 27 to 32 |
| Item | Manual Motor Starter |
| Width | 45 mm |
| Number of Poles | 3 |
| Max. Voltage | 600V AC |
| HP @ 3 Phase - 480V | 20 hp |
| HP @ 3 Phase - 240V | 10 hp |
| HP @ 1 Phase - 120V | 2 hp |
| Pilot Light | No |
| Standards | Eclass 27-37-04-01, ETIM EC000074, ETIM EC000074 IDEA 4845 |
| HP @ 3 Phase - 208V | 10 hp |
| HP @ 1 Phase - 230V | 5 hp |
| Description/Special Features | Thermal-Magnetic Trip Mechanism |
| Frame / Series / Class / Code | S0 |
| Phase Loss Sensitivity | No |
| rated service short-circuit breaking capacity Ics at 400 V, 50 Hz | 55000 ampere |
| Lowest value of setting range for overload tripper | 27 ampere |
| Integrated auxiliary switch present | No |
| Release system | magnetic |
| description of product type | 3RV2 |
| Manner of using | Toggle |
| Integrated undervoltage tripper present | No |
| max. rated operating voltage | 690 volt |
| Pole number | 3 |
| Power loss per pole, current-dependent [PlIp] | 4.4 W |
| Sensitive to phase failure | Yes |
| Number of auxiliary contacts as shutter | 0 |
| Greatest value of overload release adjustment range | 32 ampere |
| Rated operating power with AC-3, 400 V | 15 kilowatt |
| Rated operating power with AC-3, 230 V | 8 kW |
| Rated current [In] for the power loss specification | 32 ampere |
| Rated permanent current Iu | 32 ampere |
| min. rated operating voltage | 690 volt |
| Connection type | Screw connection |
| Protection type IP | IP20 |
| Number of auxiliary contacts as opener | 0 |
| Maximum Operating Temperature | 140 deg F |
| Mounting Hole Diameter | 1.38 in |
| Includes Pilot Light | No |
| Horsepower @ Single Phase - 240V AC | 5 HP |
| Current AC | 32 A |
| Mechanical Operating Durability | 100,000 |
| Mounting Style | DIN Rail |
| Starter Style | IEC |
| Horsepower @ Three Phase - 480V AC | 20 HP |
| Horsepower @ Single Phase - 120V AC | 2 HP |
| Minimum Operating Temperature | -4 deg F |
| Phase | Three |
| Terminal Connection Type | Screw Terminals |
| Overall Height | 4.7 in |
| Minimum Overload Relay Current Setting | 27 A |
| Series | Sirius 3RV20 |
| NEMA Enclosure Rating | No Enclosure |
| Maximum Overload Relay Current Setting | 32 A |
| Horsepower @ Three Phase - 208V AC | 10 HP |
| Maximum Voltage Rating | 690 V AC |
| IP Rating | IP20 |
| Overall Depth | 4.35 in |
| Electrical Operating Durability | 100,000 |
| Horsepower @ Three Phase - 240V AC | 10 HP |
| Overall Width | 4.35 in |
| Frequency | 50/60 Hz |
| Overload Protection Type | Thermal |
| Package Quantity | 1 |