MC HCF, Metal Clad Building Cable, Copper, 12 AWG, 2C with Ground, Green, Solid, 250 ft
| Item |
Metal Clad Building Cable |
| Trade Designation |
MC HCF |
| Wire Size |
12 AWG |
| Conductor Material |
Copper |
| Number of Conductors |
2C with Ground |
| Wire Color |
Black/Green/White |
| Jacket Color |
Green |
| Jacket Material |
Aluminum |
| Conductor Design |
Solid |
| Insulation Material |
PVC, Nylon |
| Voltage |
600 V |
| Length |
250 ft |
| Temp. Rating |
-14 Degrees to 90 Degrees C Dry |
| Standards |
UL 83, 1063, 1569, NFPA 70, National Electrical Code, Federal Specification A-A59544 (Formerly J-C-30B), IEEE 1202, Vertical Cable Tray Flame Test, Listed for Use In UL 1, 2, and 3 Hour Through Penetration Firestop Systems |
| Max. Amps |
20 |
| Application |
Indoor |
| Nominal Outside Dia. |
0.447 in |
| Stranding |
1 |
| Packaging |
Coil |
| Insulation Thickness (Mils) |
15 mil |
| Construction |
ConstructionSouthwire HCF MCAP® Type MC Cable is constructed with solid soft-drawn copper Type THHN circuit conductors (rated 90ºC dry), redundant grounding provided by an armor assembly comprised of interlocked armor with a bare aluminum grounding/ bonding conductor, and a green insulated copper grounding conductor. The insulated circuit and grounding conductors are cabled together and wrapped with a binder tape bearing the print legend. The bare aluminum grounding/bonding conductor is located outside the binding tape and has the same lay as the insulated conductors. Green Aluminum interlocked armor is snugly wrapped around the conductor assembly. To insure proper cable termination, refer to the installation instructions provided with every reel and coil. |
| Applications |
ApplicationSouthwire HCF MCAP® Type MC Cable is suitable for use as follows:Branch-circuit wiring for patient care areas of hospitals, medical centers, and other health care facilities (when installed in accordance with NEC® Articles 517 and 330, and mechanically protected per Article 300.4). Such areas include nursing homes, dental offices, clinics, and outpatient facilities. Use in hazardous anesthetizing areas is prohibited.Applications requiring redundant, dedicated or isolated grounding paths.Environmental air-handling spaces per NEC® 300.22(C)Fished or embedded in plaster.Places of Assembly per NEC® 518.4 and theaters per NEC® 520.5.Installation in cable tray and approved raceways.Under raised floors for information technology equipment conductors and cables per NEC® 645.5(D) & 645.5(D)(2).Use with UL Listed MCI-A fittings |
| Package Quantity |
1 |