Metal Clad Building Cable, MC, 12 AWG, 2C with Ground C, Silver, Aluminum, Solid, 600V AC, 250 ft
| Item | Metal Clad Building Cable |
|---|---|
| Trade Designation | MC |
| Wire Size | 12 AWG |
| Conductor Material | Copper |
| Number of Conductors | 2C with Ground |
| Wire Color | Gray/Green/Yellow |
| Jacket Color | Silver |
| Jacket Material | Aluminum |
| Conductor Design | Solid |
| Insulation Material | PVC |
| Voltage | 600V AC |
| Length | 250 ft |
| Temp. Rating | 194° F |
| Standards | UL Listed |
| Nominal Outside Dia. | 0.475 in |
| Application | Outdoor Use |
| Max. Amps | 20 |
| Stranding | 1 |
| Conductor Size | 12 AWG |
| Packaging | Coil |
| Shielding | Shielded |
| Shielding Material | Aluminum |
| Overall Length | 250 ft |
| Insulation Thickness (Mils) | 15 mil |
| Construction | ConstructionSouthwire Armorlite® Type MC Cable is constructed with soft-drawn copper, Type THHN/THWN conductors rated 90°C dry available in sizes 14 AWG through 2 AWG, and a green insulated grounding conductor. The conductors are cabled together and a binder tape bearing the print legend is wrapped around the assembly. Aluminum interlocking armor is applied over the assembly. |
| Applications | ApplicationSouthwire Armorlite® Type MC Cable is suitable for use as follows:Branch, feeder and service power distribution in commercial, industrial, institutional, and multiresidential buildings.Fished or embedded in plaster.Concealed or exposed installationsEnvironmental air-handling spaces per NEC 300.22 (C).Places of Assembly per NEC 518.4 and theaters per NEC 520.5.Installation in cable tray and approved raceways.Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2).Class I Div. 2, Class II Div 2, & Class III Div. 1 Hazardous Locations. |
| Temperature Rating - Maximum Wet | Not Applicable |
| Number of Strands | 1 |
| Number of Ground Conductors | 1 |
| Grounding Conductor Material | Copper |
| Number of Shielded Pairs | 0 |
| Includes Bonding Wire | No Bonding Wire |
| Hazardous Location Specification | Class I, Div 2, Group A, B, C, D, Class II, Div 2, Group E, F, G, Class III, Div 1 |
| Series | Armorlite(R) |
| Grounding Conductor Insulation Color | Green |
| Number of Neutrals | 0 |
| Conductor Insulation Color | Gray, Yellow |
| Grounding Conductor Size | 12 AWG |
| Trade Designation - Conductors | THHN |
| Conductor Insulation Material | PVC |
| Grounding Conductor Insulation Material | Not Applicable |
| Nominal Outside Diameter | 0.48 in |
| Temperature Rating - Maximum Dry | 194 deg F |
| Package Quantity | 1 |