El Cable de Edificio Blindado Southwire es ideal para instalaciones eléctricas en edificios, resistente y seguro, con un calibre de 12 AWG, 3 conductores con tierra, fabricado en aluminio sólido. Soporta una tensión de 600V AC y tiene una longitud de 250 pies.
| Item | Metal Clad Building Cable |
|---|---|
| Trade Designation | MC |
| Wire Size | 12 AWG |
| Conductor Material | Copper |
| Number of Conductors | 3C with Ground |
| Wire Color | Black/Green/Red/White |
| Jacket Color | Silver |
| Jacket Material | Aluminum |
| Conductor Design | Solid |
| Insulation Material | PVC, Nylon |
| Voltage | 600V AC |
| Length | 250 ft |
| Temp. Rating | -14° to 90° C |
| Standards | UL 83, 1569, 1685, NEC Article 330, Federal Specification A-A59544 (Formerly J-C-30B), FT4/IEEE 1202, Vertical Cable Tray Flame Test, Listed for Use In UL 1, 2 and 3 Hour Through Penetration Firestop Systems |
| Nominal Outside Dia. | 0.505 in |
| Max. Amps | 20 |
| Application | Indoor |
| Stranding | 1 |
| Conductor Size | 12 AWG |
| Packaging | Coil |
| Shielding | Shielded |
| Shielding Material | Aluminum |
| Overall Length | 250 ft |
| Insulation Thickness (Mils) | 15 mil |
| Construction | ConstructionSouthwire Armorlite® Type MC Cable is constructed with soft-drawn copper, Type THHN/THWN conductors rated 90°C dry available in sizes 14 AWG through 2 AWG, and a green insulated grounding conductor. The conductors are cabled together and a binder tape bearing the print legend is wrapped around the assembly. Aluminum interlocking armor is applied over the assembly. |
| Applications | ApplicationSouthwire Armorlite® Type MC Cable is suitable for use as follows:Branch, feeder and service power distribution in commercial, industrial, institutional, and multiresidential buildings.Fished or embedded in plaster.Concealed or exposed installationsEnvironmental air-handling spaces per NEC 300.22 (C).Places of Assembly per NEC 518.4 and theaters per NEC 520.5.Installation in cable tray and approved raceways.Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2).Class I Div. 2, Class II Div 2, & Class III Div. 1 Hazardous Locations. |
| Nominal Outside Diameter | 0.51 in |
| Temperature Rating - Maximum Dry | 194 deg F |
| Operating Temperature - Minimum | -6.8 Degrees F |
| Number of Strands | 1 |
| Series | Armorlite(R) |
| Hazardous Location Specification | Class I, Div 2, Group A, B, C, D, Class II, Div 2, Group E, F, G, Class III, Div 1 |
| Grounding Conductor Size | 12 AWG |
| Number of Neutrals | 0 |
| Grounding Conductor Material | Copper |
| Grounding Conductor Insulation Material | Not Applicable |
| Conductor Insulation Material | Nylon, PVC |
| Includes Bonding Wire | No Bonding Wire |
| Conductor Insulation Color | White, Black, Red |
| Temperature Rating - Maximum Wet | Not Applicable |
| Number of Ground Conductors | 1 |
| Grounding Conductor Insulation Color | Green |
| Number of Shielded Pairs | 0 |
| Trade Designation - Conductors | THHN |
| Package Quantity | 1 |