El Cable de Construcción con Blindaje Metálico Southwire es ideal para aplicaciones eléctricas en edificaciones. Con calibre 14 AWG, 3 conductores con tierra, hecho de aluminio sólido y con capacidad de 600V CA, este cable de 250 pies es confiable y duradero.
| Item | Metal Clad Building Cable |
|---|---|
| Trade Designation | MC |
| Wire Size | 14 AWG |
| Conductor Material | Aluminum |
| Number of Conductors | 3C with Ground |
| Wire Color | Bare/Black/Red/White |
| Jacket Color | Silver |
| Jacket Material | Aluminum |
| Conductor Design | Solid |
| Insulation Material | PVC, Nylon |
| Voltage | 600V AC |
| Length | 250 ft |
| Temp. Rating | 194° F |
| Standards | UL Listed |
| Nominal Outside Dia. | 0.41 in |
| Max. Amps | 15 |
| Conductor Size | 14 AWG |
| Stranding | 1 |
| Packaging | Coil |
| Shielding | Shielded |
| Shielding Material | Aluminum |
| Overall Length | 250 ft |
| Construction | ConstructionSouthwire MCAP® Type MC Cable is constructed with solid soft-drawn copper Type THHN circuit conductors rated 90ºC dry and a full-sized bare 8000 Series aluminum grounding/bonding conductor. This cable is available in sizes 14-8 AWG. The insulated conductors are cabled together and wrapped with a binder tape bearing the print legend. The bare aluminum grounding/bonding conductor is located outside the binding tape and has the same lay as the insulated conductors. Aluminum interlocking armor is snugly applied over the assembly. The aluminum armor and bare aluminum conductor are in intimate contact and together form the equipment ground path. To ensure proper installation, refer to the installation instructions provided with every reel and coil.An armor assembly that is an equipment grounding conductor per NEC 250.118(10)(b).Installation instructions included with every reel and coil.Simplified product application and installation over other armored products.Faster conductor make-up, wiring device installation and trim-out when grounding bonding conductor is terminated per installation instructions.Reduces installation costs up to 50% over pipe and wire.UL Classified 1, 2, and 3 hour Through Penetration Firestop Systems: W-J-3037, W-L-3110, W-L-3113, W-L-3117, W-L-3120, W-L-3121, W-L-3160, C-AJ-3115, C-AJ-3140, C-AJ-3142, C-AJ-3145, C-AJ-3173, C-AJ-3202, C-AJ-4065, C-AJ-4066, F-C-3038.Cable reverse wound on reel for ease of pulling and installation. When pulling from coils, pull from inside to ensure ease of installation.Anti-short bushings are not required for use with MC cable per the NEC and UL |
| Insulation Thickness (Mils) | 15 mil |
| Applications | ApplicationSouthwire MCAP® Type MC Cable - All Purpose is suitable for use as follows:Wherever standard AC or MC Cable is permitted.Branch circuit wiring in commercial, industrial, institutional, and multi-residential buildings.Fished or embedded in plaster.Concealed or exposed installations.Environmental air-handling spaces per NEC 300.22 (C).Places of Assembly per NEC 518.4 and theaters per NEC 520.5.Installation in cable tray and approved raceways.Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2).Use UL Listed Type MCI-A connectors |
| Conductor Insulation Color | White, Black, Red |
| Grounding Conductor Insulation Material | Uninsulated |
| Trade Designation - Conductors | THHN |
| Number of Neutrals | 0 |
| Includes Bonding Wire | Bonding Wire Included |
| Grounding Conductor Insulation Color | Bare |
| Number of Strands | 1 |
| Hazardous Location Specification | Not Applicable |
| Series | MCAP |
| Nominal Outside Diameter | 0.41 in |
| Conductor Insulation Material | Nylon, PVC |
| Grounding Conductor Material | Aluminum |
| Number of Ground Conductors | 1 |
| Temperature Rating - Maximum Dry | 194 deg F |
| Grounding Conductor Size | 12 AWG |
| Temperature Rating - Maximum Wet | Not Applicable |
| Number of Shielded Pairs | 0 |
| Package Quantity | 1 |