El Cable de construcción con recubrimiento metálico Southwire es perfecto para instalaciones eléctricas en edificaciones. Con conductores de aluminio sólido de calibre 14 y una capa de protección plateada, este cable garantiza un suministro eléctrico seguro y confiable. Con una capacidad de 600V AC y una longitud de 250 pies, este cable es ideal para aplicaciones residenciales y comerciales.
| Item | Metal Clad Building Cable |
|---|---|
| Trade Designation | MC |
| Wire Size | 14 AWG |
| Conductor Material | Copper |
| Number of Conductors | 3C with Ground |
| Wire Color | Black/Green/Red/White |
| Jacket Color | Silver |
| Jacket Material | Aluminum |
| Conductor Design | Solid |
| Insulation Material | PVC, Nylon |
| Voltage | 600V AC |
| Length | 250 ft |
| Temp. Rating | -14° to 90° C |
| Standards | UL 83, 1569, 1685, NEC Article 330, Federal Specification A-A59544 (Formerly J-C-30B), FT4/IEEE 1202, Vertical Cable Tray Flame Test, Listed for Use In UL 1, 2 and 3 Hour Through Penetration Firestop Systems |
| Max. Amps | 15 |
| Application | Indoor |
| Nominal Outside Dia. | 0.464 in |
| Conductor Size | 14 AWG |
| Stranding | 1 |
| Packaging | Coil |
| Shielding | Shielded |
| Overall Length | 250 ft |
| Shielding Material | Aluminum |
| Applications | ApplicationSouthwire Armorlite® Type MC Cable is suitable for use as follows:Branch, feeder and service power distribution in commercial, industrial, institutional, and multiresidential buildings.Fished or embedded in plaster.Concealed or exposed installationsEnvironmental air-handling spaces per NEC 300.22 (C).Places of Assembly per NEC 518.4 and theaters per NEC 520.5.Installation in cable tray and approved raceways.Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2).Class I Div. 2, Class II Div 2, & Class III Div. 1 Hazardous Locations. |
| Construction | ConstructionSouthwire Armorlite® Type MC Cable is constructed with soft-drawn copper, Type THHN/THWN conductors rated 90°C dry available in sizes 14 AWG through 2 AWG, and a green insulated grounding conductor. The conductors are cabled together and a binder tape bearing the print legend is wrapped around the assembly. Aluminum interlocking armor is applied over the assembly. |
| Insulation Thickness (Mils) | 15 mil |
| Trade Designation - Conductors | THHN |
| Grounding Conductor Insulation Color | Green |
| Number of Ground Conductors | 1 |
| Includes Bonding Wire | No Bonding Wire |
| Conductor Insulation Material | Nylon, PVC |
| Series | Armorlite(R) |
| Grounding Conductor Size | 14 AWG |
| Grounding Conductor Material | Copper |
| Nominal Outside Diameter | 0.46 in |
| Conductor Insulation Color | White, Black, Red |
| Temperature Rating - Maximum Dry | 194 deg F |
| Number of Strands | 1 |
| Grounding Conductor Insulation Material | Not Applicable |
| Operating Temperature - Minimum | -6.8 Degrees F |
| Temperature Rating - Maximum Wet | Not Applicable |
| Number of Shielded Pairs | 0 |
| Hazardous Location Specification | Class I, Div 2, Group A, B, C, D, Class II, Div 2, Group E, F, G, Class III, Div 1 |
| Number of Neutrals | 0 |
| Package Quantity | 1 |