Isolation Transformer, 250 VA, Not Rated, 120V AC, 120V AC
| Item | Isolation Transformer |
|---|---|
| Input Voltage - Transformer | 120V AC |
| Mounting - Transformer | Desk Top |
| Hz - Electrical | 60 |
| IP Rating | Not Rated |
| Outdoor Rated - Transformer | No |
| Color | White |
| Includes | (2) Output Receptacles, Hospital-Grade Input Plug, Lighted Power Switch, Power Cord |
| Depth | 7-3/4 in |
| Cord Length | 10 ft |
| NEMA Receptacle Configuration | 5-15R |
| VA Rating - Transformer | 250 VA |
| Phase - Electrical | 1 |
| Number of Outlets | 2 |
| Width | 4-3/4 in |
| Output Voltage - Transformer | 120V AC |
| Height | 4-1/2 in |
| NEMA Plug Configuration | 5-15P |
| Enclosure Type | Tower |
| Temp. Rise | Not Rated |
| Standards | RoHS, TAA, UL 60601-1 |
| Efficiency | 0.96 |
| Let-through Voltage (Combination Wave) | 250V, L-N L-G: 250V N-G: 0.5V |
| Let-through Voltage (Ring Wave) | 20V L-G: 20V N-G: 0.5V, L-N |
| Total Harmonic Distortion | Less than 1% |
| Cooling Method | Convection |
| Noise Suppression Rating | 35-65 DB |
| Output Amp Capacity | 2.1 |
| Protection Method | 2.5A circuit breaker |
| Leakage Current | Less than 100 microamps |
| Additional Information | Transformer Type: Medical grade, low impedance transformer-based line isolation transformer, Removes EMI/RFI noise, utility switching transients, load-generated harmonics and ground loops, Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode, Suppression Joule Rating: 680 (510 input/170 output), Leakage Current: As low as 100 microamps, Noise Suppression Rating: 35 to 65 DB, Total Harmonic Distortion: Less than 1%, Over Current Protection: 2A circuit breaker, Cooling Method: Convection, Efficiency: 96%, Let-through Voltage (Ring Wave): L-N: 20 V, L-G: 20 V, N-G: 0.5 V Let-through Voltage (Combination Wave): L-N: 250 V, L-G: 250 V, N-G: 0.5 V |
| Package Contents | IS250HG, IS250HG Isolation Transformer, Instruction manual with warranty information |
| TAA Compliant | Yes |
| Certifications & Standards | cUL, UL 2601-1, UL (UL Series AGIS250YWN) |
| Output Receptacle Detail | 2 x NEMA 5-15R |
| Input Cord Length (ft.) | 10 |
| Over Current Protection | 2.5A circuit breaker |
| Product Compliance | Trade Agreements Act (TAA) |
| Input Plug Type | NEMA 5-15P-HG |
| Product Certifications | UL 60601-1 |
| Package Includes | IS250HG Isolation Transformer;Instruction manual with warranty information |
| Output Receptacles | (2) 5-15R-HG |
| Includes Circuit Breaker | Circuit Breaker Included |
| Hospital Grade Outlets | Hospital Grade |
| Package Quantity | 1 |