| Item | Line Interactive UPS |
|---|---|
| UPS Type | Line Interactive |
| Power Rating | 3 kVA |
| Mounting | Tower, Rack |
| Wattage | 2.88 kW |
| Input Voltage | 120V AC |
| Output Voltage | 127/120/110V AC |
| Backup Time (Half/Full Load) | 11 min/4 min |
| Number of Outlets | 7 |
| Width | 24 in |
| NEMA Plug Configuration | L5-30P |
| Transfer Time | 4 ms |
| Height | 3-1/2 in |
| Input Current | 24 A |
| Hz | 50/60 Hz |
| NEMA Receptacle Configuration | 5-15R, L5-30R |
| Depth | 24 in |
| Standards | UL1778, CSA, FCC Part 15 Class A, NOM |
| Housing Material | Steel |
| Load Capacity | 3000 VA/2880 W |
| Serial Port | Yes |
| USB | Yes |
| Network Management | SNMP Manageable |
| Package Contents | SmartPro SMART3000RMOD2U 3000VA Tower/Rack Mountable UPS, PowerAlert Software with USB, DB9 and EPO Cabling, 4 x Post Rack Mount Installation Accessories, Owner's Manual with Warranty Information |
| Hot Swappable | Yes |
| Software Included | PowerAlert Software |
| Emergency Power OFF | Yes |
| Form Factor | Tower, Rack |
| Rack Height | 2 U |
| Typical Battery Recharge Time | 4 hr |
| Additional Information | 2 x Front Panel Switches offer Power On/Off Control, Alarm Cancel, Self Test and UPS Voltage Configuration, Surge Suppression: 800 JoulesFront Panel LEDs: Utility Power, Voltage Regulation, On-Battery, Overload, Replace Battery, Site Wiring Fault, UPS Fault ConditionsAlarms: Power Failure, Overload, Low Battery |
| Low Voltage Transfer to Battery Power (Setpoint) | 90 |
| UPS AC Suppression Joule Rating | 800 |
| Battery Recharge Rate (Included Batteries) | Less than 4 hours to 90% (typical, full load discharge) |
| Battery Access | Front panel battery access door |
| Output Circuit Breakers | 15A (x2) - breaker 1 covers 2 5-15R outlets, breaker 2 covers 4 5-15R outlets, L5-30R outlet is unbreakered |
| Operating Temperature Range | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
| Input Cord Length (ft.) | 10 |
| Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported |
| Minimum Required Rack Depth (inches) | 35 |
| Output Voltage Regulation (Battery Mode) | +/-5% |
| Network Management Cards | WEBCARDLX, SNMPWEBCARD, RELAYIOCARD |
| Expandable Runtime | Yes |
| External Battery Pack Compatibility | BP72V15-2U (limit 1); BP72V28RT-3U (multi-pack compatible); BP72V18-2US (multi-pack compatible) |
| Primary UPS Height (mm) | 89 |
| Output Capacity (Watts) | 2,880 |
| Load Management Receptacles | Two switchable load banks - bank one consists of 2 5-15R outlets, bank 2 consists of 4 5-15R outlets |
| High Voltage Transfer to Battery Power (Setpoint) | 146 |
| Cooling Method | Fan |
| Network Monitoring Port Description | Supports detailed monitoring of UPS and site power conditions |
| Nominal Input Voltage(s) Supported | 110 V AC, 120 V AC, 127 V AC |
| Recommended Electrical Service | 30A 120V |
| Alarm Cancel Operation | Power-fail alarm can be silenced by pressing the on/test/mute switch |
| Battery Mode Heat Dissipation (BTU/Hr) @ Full Load | 1,601 |
| Primary Form Factor | Rackmount |
| Audible Alarm | Audible alarm indicates on battery, low battery and overload warnings |
| Primary UPS Depth (mm) | 610 |
| Power Factor | 0.96 |
| UPS Input Cord Length (ft.) | 10 |
| Site Wiring Fault Indication | Includes site wiring fault LED |
| Undervoltage Correction | Input voltages between 101 and 110 are boosted by 15% |
| Included Mounting Accessory Description | 4 post rackmount installation accessories included |
| AC Mode BTU / Hr. (Full Load) | 518 |
| Output Capacity (VA) | 3,000 |
| Nominal Output Voltage(s) Supported | 110 V, 120 V, 127 V |
| AC Suppression Response Time | Instantaneous |
| AC Mode Efficiency Rating (100% Load) | 0.95 |
| LED Indicators | 14 LEDs indicate line power, power fail, avr, fault, overload, replace battery and site wiring fault conditions; includes 5 LED load and battery charge meter |
| UPS Power Module Dimensions (hwd, in.) | 3.5 x 17.5 x 24 |
| DC System Voltage (VDC) | 72 |
| Severe Undervoltage Correction | Input voltages between 90 and 100 are boosted by 30% |
| EMI / RFI AC Noise Suppression | Yes |
| Rated input current (Maximum Load) | 24 A |
| Overvoltage Correction | Input voltages between 132 and 146 are reduced by 12% |
| Communications Interface | DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled) |
| Output AC Waveform (Battery Mode) | Pure Sine wave |
| Switches | 2 Switches control off/on power status and alarm-cancel/self-test operation |
| Individually Controllable Load Banks | Yes |
| High Availability UPS Features | Hot swappable batteries; Hot swappable UPS power module |
| Output Capacity Details | 2400W max capacity with external battery packs connected |
| Installation Form Factors Supported with Optional Accessories | 2 post rackmount ( 2POSTRMKITWM ); Wallmount ( 2POSTRMKITWM ); Tower ( 2-9USTAND ) |
| Communications Cable | USB, DB9 and EPO cabling included |
| AC Suppression Joule Rating | 800 |
| Storage Temperature Range | +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
| Frequency Compatibility Details | Automatic frequency selection |
| Relative Humidity | 0 to 95%, non-condensing |
| Package Includes | UPS chassis pre-loaded with hot-swappable UPS electronics module and internal battery module;USB, DB9 and EPO cabling;4 post rackmount installation accessories;Owner's manual |
| Internal UPS Replacement Battery Cartridge | RBC96-RMOD2U |
| Voltage Regulation Description | Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 90 to 146 |
| Input Phase | Single-Phase |
| Battery Replacement Description | Hot-swappable, replaceable batteries |
| Output Voltage Regulation (Line Mode) | 120V: -7% +9%, 110V: -8% + 11%, 127V: -9% +9% |
| Package Quantity | 1 |