Smart UPS, 1000VA, Line Interactive, Out: 110/115/120V In: 120V AC
| Item |
Smart UPS |
| UPS Type |
Line Interactive |
| Power Rating |
1,000 VA |
| Mounting |
Tower |
| Wattage |
560 W |
| Input Voltage |
120V AC |
| Output Voltage |
110/115/120V |
| Backup Time (Half/Full Load) |
12 min/2 min |
| Outlet Type |
(2) Surge; (6) UPS/Surge |
| Number of Outlets |
8 |
| Housing Material |
ABS |
| Width |
15 in |
| NEMA Plug Configuration |
5-15P |
| Hz |
50/60 Hz |
| Transfer Time |
6 milliseconds typical (10 milliseconds max) |
| NEMA Receptacle Configuration |
5-15R |
| Expandable Runtime |
No |
| Installation Form Factors Supported with Included Accessories |
Tower |
| Battery Replacement Description |
Replaceable internal batteries (see manual) |
| UPS Certifications |
Meets FCC Part 15 Category A (EMI); Tested to CSA (Canada); Tested to NOM (Mexico); Tested to UL1778 (USA) |
| Primary Form Factor |
Tower |
| Recommended Electrical Service |
15A 120V |
| High Voltage Transfer to Battery Power (Setpoint) |
145 |
| Battery Access |
Battery access door |
| Cold Start (Startup in Battery Mode During a Power Failure) |
Cold-start operation supported |
| Nominal Input Voltage(s) Supported |
120 V AC |
| Input Phase |
Single-Phase |
| Communications Cable |
USB interface cable included |
| PowerAlert Software |
For local monitoring via the UPS™s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert |
| UPS Certification Details |
UL1778: 2014 5th EDITION; CAN/CSA-C22.2 NO. 107.3:2014 3rd EDITION; FCC CLASS A; FCC Part 68 Approved (#5WSWP01B005); Industry Canada Approved (#3449A-005, REN0.1B); RETIE (Colombia) |
| Voltage Regulation Description |
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 89 to 145 |
| Low Voltage Transfer to Battery Power (Setpoint) |
89 |
| Rated input current (Maximum Load) |
12 A |
| Output Voltage Regulation (Battery Mode) |
120V (±10%) |
| Communications Interface |
USB (HID enabled) |
| Output Voltage Regulation (Line Mode) |
120V |
| Overvoltage Correction |
Input voltages between 128 and 149 are reduced by 15% |
| WatchDog Compatibility |
Supports Watchdog application, OS and hard-reboot restart options for remote applications |
| AC Mode Efficiency Rating (100% Load) |
>95% |
| Nominal Output Voltage(s) Supported |
110 V, 115 V, 120 V |
| AC Mode BTU / Hr. (Full Load) |
25.3 |
| Operating Temperature Range |
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
| UPS Power Module Dimensions (hwd, in.) |
7.5 x 5.5 x 15 |
| Primary UPS Depth (mm) |
381 |
| DC System Voltage (VDC) |
12 |
| High Availability UPS Features |
Battery Independent Restart |
| Switches |
Power off/on switch |
| UPS Dataline Suppression |
1 line TEL/DSL or Ethernet |
| Output Watt Capacity (Watts) |
560 |
| Full Load Runtime (min.) |
2 min |
| Half Load Runtime (min.) |
12 min |
| Battery Recharge Rate (Included Batteries) |
8 hours (10% to 90%) |
| Undervoltage Correction |
Input voltages between 89 and 108 are boosted by 18% |
| Output AC Waveform (Battery Mode) |
PWM sine wave |
| Input Circuit Breakers |
15A |
| Output Volt Amp Capacity (VA) |
1,000 |
| UPS AC Suppression Joule Rating |
316 |
| UPS Input Cord Length (ft.) |
5 |
| Individually Controllable Load Banks |
No |
| Relative Humidity |
0 to 90%, non-condensing |
| Primary UPS Height (mm) |
191 |
| UPS AC Suppression Response Time |
Instantaneous |
| Output kVA Capacity (kVA) |
1 |
| Storage Temperature Range |
to +45 degrees Celsius |
| Audible Alarm |
UPS remains silent in battery backup mode; Alarm sounds only to report low-battery, fault, overload and replace-battery conditions |
| EMI / RFI AC Noise Suppression |
Yes |
| Front Panel LCD Display |
Touchscreen LCD reports input voltage, output voltage, load percentage, battery charge percentage and overload status |
| Package Quantity |
1 |