Smart UPS, 3kVA, Online, Out: 120V AC In: 120V AC
| Item | Smart UPS |
|---|---|
| UPS Type | Online |
| Power Rating | 3 kVA |
| Mounting | Rack |
| Wattage | 2,400 W |
| Input Voltage | 120V AC |
| Output Voltage | 120V AC |
| Backup Time (Half/Full Load) | 14 min/5 min |
| Number of Outlets | 9 |
| Transfer Time | No transfer time (0 ms.) in online, double-conversion mode |
| Standards | UL1778 (USA), CSA (Canada), NOM (Mexico), FCC Part 15 Category A (EMI) |
| Width | 26 in |
| Height | 5.2 in |
| NEMA Plug Configuration | L5-30P |
| NEMA Receptacle Configuration | L5-30R, 5-15R; 5-15/20R |
| Depth | 26 in |
| Cord Length | 10 ft |
| Input Current | 24 A |
| Hz | 50/60 Hz |
| Housing Material | Steel |
| Battery Type | VRLA |
| Primary UPS Depth (mm) | 660 |
| Low Voltage Transfer to Battery Power (Setpoint) | 80V (100% load), 65V ( <70% load) |
| Voltage Regulation Description | Online, double-conversion power conditioning |
| UPS AC Suppression Joule Rating | 510 |
| Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported |
| WatchDog Compatibility | Supports Watchdog application, OS and hard-reboot restart options for remote applications |
| Output Voltage Regulation (Battery Mode) | +/- 2% |
| Output Capacity Details | OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 3 minutes; 150% load for 30 seconds and >150% load for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits) |
| Frequency Compatibility Details | Output frequency matches input nominal on startup, defaults to 60 Hz on cold-start |
| AC Mode BTU / Hr. (Full Load) | 1,117 |
| External Battery Pack Compatibility | BP72V15-2U (limit 1); BP72V28RT-3U (multi-pack compatible); BP72V18 -2US (multi-pack compatible) |
| Storage Temperature Range | +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
| Output kVA Capacity (kVA) | 3 |
| Individually Controllable Load Banks | Yes |
| Communications Interface | Contact closure; DB9 Serial; EPO (emergency power off); Pre-installed network card; Slot for SNMP/Web interface; USB (HID enabled) |
| Severe Undervoltage Correction | 2% output voltage regulation during undervoltages to 65 (under 70% load only) |
| Output Voltage Regulation (Line Mode) | +/- 2% |
| UPS Dataline Suppression | 1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet |
| UPS Power Module Dimensions (hwd, in.) | 5.2 x 17.8 x 26 |
| Rated input current (Maximum Load) | 24A |
| Minimum Required Rack Depth without External Battery Pack (in.) | 31.5 |
| Included Mounting Accessory Description | Includes 4 post rackmount installation accessories |
| High Voltage Transfer to Battery Power (Setpoint) | 150 |
| Overvoltage Correction | 2% output voltage regulation during overvoltages to 150 |
| Cooling Method | Fan |
| Power Factor | 0.8 |
| Battery Recharge Rate (Included Batteries) | Less than 6 hours from 10% to 80% (typical, full load discharge) |
| Battery Replacement Description | Hot-swappable, user replaceable batteries |
| Expandable Runtime | Yes |
| EMI / RFI AC Noise Suppression | Yes |
| Output Voltage Regulation (Economy Line Mode) | +/- 10% |
| Nominal Output Voltage(s) Supported | 110 V, 120 V |
| Output kW Capacity (kW) | 2.4 |
| Input Phase | Single-Phase |
| Battery Mode BTU / Hr. (Full Load) | 1,224 |
| Output Volt Amp Capacity (VA) | 3,000 |
| Output Circuit Breakers | 15A branch rated (x2) - each breaker protects 4 outlets, L5-30R is unbreakered |
| LED Indicators | 14 LEDs indicate line power, online mode, economy/bypass mode, on-battery, overload, battery low, replace battery and fault status information; 4-LED meter displays load and battery charge levels; LED panel rotates for viewing in rack/tower formats |
| Output AC Waveform (Battery Mode) | Pure Sine wave |
| Expandable Battery Runtime | Supports extended runtime with optional external battery packs |
| Crest Factor | 0.125694444444444 |
| Half Load Runtime (min.) | 14 min |
| Nominal Input Voltage(s) Supported | 110 V AC, 120 V AC |
| UPS Certifications | Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI) |
| Recommended Electrical Service | 30A 120V |
| Input Circuit Breakers | 40A |
| DC System Voltage (VDC) | 72 |
| Communications Cable | USB and DB9 cabling included |
| Network Monitoring Port Description | Includes pre-installed Network Management Card; DB9 port supports RS232 and contact closure communications; Economy-mode setting option is available using PowerAlert software and DB9 Serial cable connection OR installed Network Management Card |
| Primary Form Factor | Rackmount |
| Audible Alarm | Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions |
| UPS Input Cord Length (ft.) | 10 |
| Relative Humidity | 0 to 95%, non-condensing |
| Installation Form Factors Supported with Optional Accessories | 2 post rackmount ( 2POSTRMKITHD ); Tower ( 2-9USTAND ) |
| Output Watt Capacity (Watts) | 2,400 |
| Undervoltage Correction | 2% output voltage regulation during undervoltages to 80 |
| AC Economy Mode BTU / Hr. (Full Load) | 523 |
| AC Economy Mode Efficiency Rating (100% Load) | 0.94 |
| Rack Height | 3 U |
| Full Load Runtime (min.) | 5 min |
| Battery Access | Front panel battery access door |
| PowerAlert Software | For local monitoring via the UPS™s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert |
| Primary UPS Height (mm) | 132 |
| Internal UPS Replacement Battery Cartridge | RBC96-3U (quantity 1) |
| Switches | 2 Switches control off/on power status and alarm-cancel/self-test operation |
| High Availability UPS Features | Automatic inverter bypass; Hot swappable batteries |
| Operating Temperature Range | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
| Alarm Cancel Operation | Power-fail alarm can be silenced using alarm-cancel switch |
| Load Management Receptacles | Two switchable four-outlet load banks, (bank 1 - four 5-15/20R, bank 2 - four 5-15R outlets) |
| Minimum Required Rack Depth with External Battery Pack (in.) | 32 |
| UPS AC Suppression Response Time | Instantaneous |
| USB | Yes |
| Package Contents | SU3000RTXL3UN US with Pre-installed WEBCARDLX, Poweralert Software and Cabling, Mounting Hardware For 4 Post Rack Enclosures, Instruction Manual |
| Status Indicators | 14 LEDs indicate line power, online mode, economy/bypass mode, on-battery, overload, battery low, replace battery and fault status information, 4-LED meter displays load and battery charge levels, LED panel rotates for viewing in rack/tower formats |
| Waveform Type | Pure Sine, Sine Wave Wave |
| Bypass Switch | Automatic |
| Total Number of Expansion Slots | 1 |
| Circuit Breaker | Yes |
| Form Factor | Tower, Rack |
| Thermal Dissipation | 326.1 W |
| Dataline Protection | RJ-11, RJ-45 |
| Maximum Operating Temperature | 104°F (40°C) |
| Software Included | Poweralert Software |
| Load Capacity | 3000 VA/2400 W |
| Serial Port | Yes |
| Emergency Power OFF | Yes |
| Hot Swappable | Yes |
| Network Management | SNMP Manageable |
| Alarm | Overload, Remote Shutdown, UPS StartUp, Low Battery, Power Failure, UPS Fault |
| Surge Energy Rating | 510 J |
| Protection Type | Brownout, EMI, RFI, Over Voltage, Under Voltage |
| Typical Battery Recharge Time | 6 hr |
| Output Capacity (Watts) | 2,400 |
| Package Includes | SU3000RTXL3UN SmartOnline 120V 3kVA 2.4kW On-Line Double-Conversion UPS;Pre-installed WEBCARDLX network interface;USB cable;DB9 cable;EPO cable;Rack-mounting hardware;Owner's manual |
| Installation Form Factors Supported with Included Accessories | 4 post 19 inch rackmount |
| Minimum Required Rack Depth (inches) | 29 |
| Product Certifications | CSA (Canada); NOM (Mexico); UL 1778 |
| Network Management Cards | WEBCARDLXE |
| UPS Applications | Mission Critical Applications |
| Output Capacity (VA) | 3,000 |
| Online Mode Heat Dissipation (BTU/Hr) @ Full Load | 1,117 |
| Product Compliance | FCC Part 15 Class A (USA) |
| Package Quantity | 1 |