UPS System, 1.5kVA, Line Interactive, Out: 110/115/120V AC In: 120V AC
| VA Rating - UPS Systems | 1.5 kVA |
|---|---|
| Item | UPS System |
| UPS Type | Line Interactive |
| Power Rating | 1.5 kVA |
| Mounting | Tower, Wall |
| Wattage | 940 W |
| Input Voltage | 120V AC |
| Output Voltage | 110/115/120V AC |
| Backup Time (Half/Full Load) | 11.5 min/4.5 min |
| Outlet Type | (3) Surge; (5) UPS/Surge |
| Medical Grade | No |
| Number of Outlets | 8 |
| Phase | Single |
| Transfer Time | 2 to 4 msec |
| Cord Length | 6 ft |
| NEMA Receptacle Configuration | 5-15R |
| Special Features | Hot Swappable Batteries |
| Automatic Volts Regulation | Yes |
| Hz | 60 Hz |
| NEMA Plug Configuration | 5-15P |
| Green Environmental Attribute | Product Contributes To Reducing Energy Consumption |
| Depth | 7 in |
| Height | 12 in |
| Fax/Modem Line Protection | Yes |
| Includes | Interactive UPS, USB and Telephone Cable |
| Display Type | No Display |
| Width | 7 in |
| Standards | CSA, FCC Part 15 Class B, NOM, RoHS, UL1778 |
| Ports | TEL/DSL, USB |
| Footnotes | USB and TEL/DSL |
| Input Current | 12 A |
| Overall Width | 7.2 in |
| Overall Height | 11.8 in |
| Capacity - Batteries | 1500 VA/940 W |
| Input Connection | NEMA 5-15P Plug |
| Battery Type | VRLA |
| Housing Material | Polycarbonate |
| High Availability UPS Features | Hot swappable batteries |
| AC Mode BTU / Hr. (Full Load) | 109 |
| Storage Temperature Range | +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
| Rated input current (Maximum Load) | 12A |
| Communications Cable | USB interface cable included |
| EMI / RFI AC Noise Suppression | Yes |
| UPS AC Suppression Response Time | Instantaneous |
| Input Frequency | 60Hz +/-5% |
| Battery Replacement Description | Hot-swappable, user replaceable batteries |
| Nominal Output Voltage(s) Supported | 110 V, 115 V, 120 V |
| Communications Interface | USB (HID enabled) |
| Audible Alarm | Audible alarm indicates power-failure and low-battery conditions |
| Output Watt Capacity (Watts) | 940 |
| Output Volt Amp Capacity (VA) | 1,500 |
| WatchDog Compatibility | Supports Watchdog application, OS and hard-reboot restart options for remote applications |
| Full Load Runtime (min.) | 4 min 30 sec |
| UPS Certifications | Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category B (EMI) |
| Low Voltage Transfer to Battery Power (Setpoint) | 75 |
| Input Phase | Single-Phase |
| Hot-Swap PDU options | PDUB15 (2U / 8 5-15R outlets) |
| Half Load Runtime (min.) | 11 min 30 sec |
| Overvoltage Correction | Input voltages between 128 and 147 are reduced by 12% |
| AC Mode Efficiency Rating (100% Load) | 0.97 |
| Output Voltage Regulation (Line Mode) | -18% +8% |
| Alarm Cancel Operation | Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status |
| Severe Undervoltage Correction | Input voltages between 75 and 92 are boosted by 30% |
| Installation Form Factors Supported with Optional Accessories | Wallmount (UPSWM - tower mounting kit) |
| Recommended Electrical Service | 15A 120V |
| Undervoltage Correction | Input voltages between 93 and 107 are boosted by 14% |
| Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported |
| PowerAlert Software | For local monitoring via the UPSâ„¢s built-in USB port, download PowerAlert Local software at http://www.tripplite.com/poweralert |
| LED Indicators | 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status |
| Battery Mode BTU / Hr. (Full Load) | 523 |
| Internal UPS Replacement Battery Cartridge | RBC24-SLT |
| Installation Form Factors Supported with Included Accessories | Tower |
| Expandable Runtime | No |
| Battery Access | Battery access door |
| Operating Temperature Range | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
| DC System Voltage (VDC) | 24 |
| Output kVA Capacity (kVA) | 1.5 |
| UPS AC Suppression Joule Rating | 510 |
| Battery Recharge Rate (Included Batteries) | Less than 4 hours from 10% to 90% |
| UPS Power Module Dimensions (hwd, in.) | 11.8 x 7.2 x 7.5 |
| UPS Dataline Suppression | 1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet |
| Primary Form Factor | Tower |
| Output AC Waveform (Battery Mode) | PWM sine wave |
| Voltage Regulation Description | Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 75 to 147 |
| Nominal Input Voltage(s) Supported | 120 V AC |
| Individually Controllable Load Banks | No |
| Primary UPS Height (mm) | 300 |
| UPS Input Cord Length (ft.) | 6 |
| Primary UPS Depth (mm) | 191 |
| Relative Humidity | 0 to 95%, non-condensing |
| Switches | 2 Switches control off/on power status and alarm-cancel/self-test operation |
| Network UPS Tools Compatibility | NUT compatible. See the full list of Tripp Lite NUT compatible UPS systems at NUT UPS Compatibility Lis |
| High Voltage Transfer to Battery Power (Setpoint) | 147 |
| Output Voltage Regulation (Battery Mode) | +/- 5% |
| Dataline Protection | RJ-11, RJ-45 |
| Typical Battery Recharge Time | 4 hr |
| Hot Swappable | Yes |
| USB | Yes |
| Product Series | VS |
| Additional Information | Switches: Includes 2 front panel switches one main on/off power switch and one dual function "alarm cancel" / "self test" button, Typical Application: Entry-level PCs, networked workstations, point-of-sale equipment, small business phone systems, audio/video equipment and home theater systems; Ideal for sensitive electronic applications in areas where brownout conditions are common |
| Form Factor | Tower |
| Package Contents | Omni VS 1500VA Tower UPS, USB and telephone cable, User manual with warranty information |
| Load Capacity | 1500 VA/940 W |
| Output Capacity (VA) | 1,500 |
| Output Capacity (Watts) | 940 |
| Product Compliance | FCC Part 15 Class B (USA) |
| Package Includes | OMNIVS1500 Line-Interactive UPS;USB and telephone cable;Owner's manual with warranty information |
| Product Certifications | CSA (Canada); NOM (Mexico); UL 1778 |
| UPS Applications | Home/Office Desktop; High-End Desktop/Small Network; Retail/Point of Sale; Hospitality |
| Overall Depth | 7-1/2 in |
| Battery Recharge Time | 4 hr |
| Manufacturer Warranty | 3 yr (Limited) |
| Operating Temperature - Maximum | 104 deg F |
| External Battery Compatible | Not External Battery Pack Compatible |
| Visible Indicator Light Conditions | Battery Low, Overload, Power Status, Replace Battery, Voltage Regulation |
| Receptacle Configuration | 5-15R |
| Battery Chemistry | Valve Regulated Lead Acid |
| Output Ports Included | USB |
| Power Rating - Real | 940 W |
| Data Line Protection | Includes Data Line Surge Protection |
| Automatic Voltage Regulation | Includes Automatic Voltage Regulation |
| Includes Battery | Battery Included |
| Power Cord Length | 6 ft |
| Number of Outlets - Surge Only | 3 |
| Operating Temperature - Minimum | 32 deg F |
| Input Current - Maximum | 12 A |
| Audible Alarm Conditions | Low Battery |
| Frequency | 60 Hz |
| Replacement Battery Part Number | RBC24-SLT |
| Package Quantity | 1 |