| VA Rating - UPS Systems | 1.5 kVA |
|---|---|
| Item | UPS System |
| UPS Type | Line Interactive |
| Power Rating | 1.5 kVA |
| Mounting | Tower, Wall |
| Wattage | 940 W |
| Input Voltage | 230V AC |
| Output Voltage | 220/230/240V AC |
| Backup Time (Half/Full Load) | 13 min/4.5 min |
| Outlet Type | UPS/Surge |
| Medical Grade | No |
| Number of Outlets | 8 |
| Hz | 50/60 Hz |
| Ports | TEL/DSL, USB |
| Footnotes | USB and TEL/DSL |
| Green Environmental Attribute | Product Contributes To Reducing Energy Consumption |
| Automatic Volts Regulation | Yes |
| Cord Length | 6 ft |
| Phase | Single |
| Includes | (2) C13 to C14 Interconnection Cables, Line Interactive UPS, USB and Phone Line Cables |
| Special Features | Hot Swappable Batteries |
| NEMA Receptacle Configuration | C13 |
| Depth | 8 in |
| Width | 8 in |
| Fax/Modem Line Protection | Yes |
| Standards | CE, IEC/EN 62040, IRAM (Argentina), RoHS, UL1778 |
| Display Type | No Display |
| NEMA Plug Configuration | C14 |
| Height | 12 in |
| Transfer Time | 2 to 4 msec |
| Input Current | 5 A |
| Overall Width | 7.2 in |
| Capacity - Batteries | 1500 VA/940 W |
| Housing Color | Black |
| Operating Temp. Range | 122°F (50°C) |
| Input Connection | NEMA 5-15P Plug |
| Housing Material | Polycarbonate |
| Battery Type | VRLA |
| Undervoltage Correction | Input voltages between 177 and 199 are boosted by 14% |
| Overvoltage Correction | Input voltages between 245 and 282 are reduced by 12% |
| Voltage Regulation Description | Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 151 to 282 |
| Battery Recharge Rate (Included Batteries) | Less than 4.5 hours from 10% to 90% |
| Battery Mode BTU / Hr. (Full Load) | 657 |
| Operating Temperature Range | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
| UPS Certification Details | CE 62040 |
| Half Load Runtime (min.) | 13 min |
| Frequency Compatibility Details | Automatic frequency selection |
| Battery Replacement Description | Hot-swappable, user replaceable batteries |
| Output kVA Capacity (kVA) | 1.5 |
| Audible Alarm | Audible alarm indicates power-failure and low-battery conditions |
| Alarm Cancel Operation | Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status |
| UPS Input Cord Length (ft.) | 0.5 |
| AC Mode BTU / Hr. (Full Load) | 99 |
| External Battery Pack Compatibility | BP24V15RT2U (limit 1); BP24V28-2U (limit 1); BP24V70-3U (multi-pack compatible) |
| Output Watt Capacity (Watts) | 940 |
| AC Mode Efficiency Rating (100% Load) | 0.97 |
| Nominal Input Voltage(s) Supported | 230 V AC |
| UPS Dataline Suppression | 1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet |
| Expandable Battery Runtime | Extended runtime supported via optional external battery packs |
| Storage Temperature Range | +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
| Output Volt Amp Capacity (VA) | 1,500 |
| Full Load Runtime (min.) | 4 min 30 sec |
| Individually Controllable Load Banks | No |
| Relative Humidity | 0 to 95%, non-condensing |
| LED Indicators | 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status |
| Input Phase | Single-Phase |
| Severe Undervoltage Correction | Input voltages between 151 and 176 are boosted by 30% |
| High Voltage Transfer to Battery Power (Setpoint) | 282 |
| Nominal Output Voltage(s) Supported | 220 V, 230 V, 240 V |
| Primary UPS Depth (mm) | 191 |
| UPS AC Suppression Response Time | Instantaneous |
| UPS Power Module Dimensions (hwd, in.) | 11.8 x 7.2 x 7.5 |
| Communications Interface | USB |
| High Availability UPS Features | Hot swappable batteries |
| EMI / RFI AC Noise Suppression | Yes |
| Communications Cable | USB interface cable included |
| Output Voltage Regulation (Battery Mode) | +/- 5% |
| Expandable Runtime | Yes |
| Primary Form Factor | Tower |
| Included Output Power Cables | Includes 2 C13 to C14 output power cables |
| Installation Form Factors Supported with Optional Accessories | Wallmount (UPSWM - tower mounting kit) |
| Battery Access | Battery access door |
| WatchDog Compatibility | Supports Watchdog application, OS and hard-reboot restart options for remote applications |
| Primary UPS Height (mm) | 300 |
| Internal UPS Replacement Battery Cartridge | RBC51 (quantity 2) |
| UPS AC Suppression Joule Rating | 340 |
| Low Voltage Transfer to Battery Power (Setpoint) | 151 |
| Rated input current (Maximum Load) | 5 A |
| PowerAlert Software | For local monitoring via the UPSâ„¢s built-in USB port, download PowerAlert Local software at http://www.tripplite.com/poweralert |
| Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported |
| UPS Certifications | Tested to UL1778 (USA); CE; Tested to GOST (Russia); Tested to SASO (Saudi Arabia); Tested to IRAM (Argentina) |
| Output Voltage Regulation (Line Mode) | -18% +8% |
| Switches | 2 Switches control off/on power status and alarm-cancel/self-test operation |
| UPS Input Connection Description | Attached 15cm line cord with C14 inlet. The C14 inlet accepts user-supplied AC power cord with country-specific plug. |
| DC System Voltage (VDC) | 24 |
| Output AC Waveform (Battery Mode) | PWM sine wave |
| Installation Form Factors Supported with Included Accessories | Tower |
| Hot-Swap PDU options | PDUBHV10 (2U / 8 C13 outlets) |
| USB | Yes |
| Status Indicators | 4 Front Panel LEDs: Line power, Battery power, Low battery, Replace battery, Voltage regulation operation |
| Surge Energy Rating | 1920 J |
| Typical Battery Recharge Time | 4 hr |
| Load Capacity | 1500 VA/940 W |
| Maximum Operating Temperature | 122°F |
| Form Factor | Tower |
| Alarm | Power Failure |
| Hot Swappable | Yes |
| Additional Information | Offers voltage regulation, surge suppression and long lasting battery support, Regulates brownouts as low as 151 and overvoltages to 282V back to usable 230V nominal levels without using battery power, 1500VA power handling ability supports a variety of sensitive electronic equipment, Runtime is further expandable with the addition of BP24V14 external battery pack, Cold Start: UPS can be "cold started" to enable temporary AC output during a power failure |
| Battery Life | 6 yr |
| Dataline Protection | RJ-11, RJ-45 |
| Waveform Type | Pulse-width Modulated Sine Wave |
| Product Series | VS |
| Package Contents | Omni VS 1500VA Tower UPS, OMNIVSINT1500XL line interactive UPS, 2 C13 to C14 interconnection cables, USB and phone line cables, Owner's manual with warranty information |
| Package Includes | OMNIVSINT1500XL line interactive UPS;2 C13 to C14 interconnection cables;USB and phone line cables;Owner's manual with warranty information |
| Product Compliance | SASO (Saudi Arabia); CE (Europe) |
| Product Certifications | GOST (Russia); IEC/EN 62040; IRAM (Argentina); UL 1778 |
| UPS Applications | Home/Office Desktop; Audio/Video; High-End Desktop/Small Network; Retail/Point of Sale; Hospitality |
| Output Capacity (VA) | 1,500 |
| Output Capacity (Watts) | 940 |
| Input Current - Maximum | 5 A |
| Power Cord Length | 6 in |
| Audible Alarm Conditions | Low Battery |
| Output Ports Included | USB |
| Manufacturer Warranty | 2 yr (Limited) |
| External Battery Compatible | External Battery Pack Compatible |
| Includes Battery | Battery Included |
| Data Line Protection | Includes Data Line Surge Protection |
| Visible Indicator Light Conditions | Battery Low, Overload, Power Status, Replace Battery, Voltage Regulation |
| Power Rating - Real | 940 W |
| Operating Temperature - Maximum | 104 deg F |
| Battery Recharge Time | 4 hr 30 min |
| Replacement Battery Part Number | RBC51 |
| Operating Temperature - Minimum | 32 deg F |
| Automatic Voltage Regulation | Includes Automatic Voltage Regulation |
| Package Quantity | 1 |