UPS System, 1kVA, Line Interactive, Out: 110/115/120V AC In: 120V AC
| VA Rating - UPS Systems | 1 kVA |
|---|---|
| Item | UPS System |
| UPS Type | Line Interactive |
| Power Rating | 1 kVA |
| Mounting | Tower, Wall |
| Wattage | 500 W |
| Input Voltage | 120V AC |
| Output Voltage | 110/115/120V AC |
| Backup Time (Half/Full Load) | 14 min/3.5 min |
| Outlet Type | (2) Surge; (6) UPS/Surge |
| Medical Grade | No |
| Number of Outlets | 8 |
| NEMA Plug Configuration | 5-15P |
| Automatic Volts Regulation | Yes |
| Display Type | No Display |
| Phase | Single |
| Green Environmental Attribute | Product Contributes To Reducing Energy Consumption |
| Includes | Interactive UPS, USB and Telephone Cable |
| Fax/Modem Line Protection | Yes |
| Hz | 60 Hz |
| Height | 11 in |
| Cord Length | 6 ft |
| NEMA Receptacle Configuration | 5-15R |
| Width | 8 in |
| Ports | TEL/DSL, USB |
| Special Features | Hot Swappable Batteries |
| Footnotes | 4,6 |
| Standards | CSA, FCC Part 15 Class B, NOM, RoHS, UL1778 |
| Input Current | 12 A |
| Transfer Time | 4 msec |
| Depth | 8 in |
| Overall Width | 5.2 in |
| Overall Height | 10.8 in |
| Capacity - Batteries | 1000 VA/500 W |
| Battery Type | Sealed Lead Acid |
| Operating Temp. Range | 122°F (50°C) |
| Housing Color | Black |
| Input Connection | NEMA 5-15P Plug |
| Housing Material | PVC |
| Output Voltage Regulation (Battery Mode) | +/- 5% |
| Primary UPS Height (mm) | 274 |
| Operating Temperature Range | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
| Individually Controllable Load Banks | No |
| Full Load Runtime (min.) | 3 min 30 sec |
| High Availability UPS Features | Hot swappable batteries |
| PowerAlert Software | For local monitoring via the UPSâ„¢s built-in USB port, download PowerAlert Local software at http://www.tripplite.com/poweralert |
| UPS Dataline Suppression | 1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet |
| Battery Replacement Description | Hot-swappable, user replaceable batteries |
| Undervoltage Correction | Input voltages between 89 and 105 are boosted by 14% |
| Switches | 2 Switches control off/on power status and alarm-cancel/self-test operation |
| Primary UPS Depth (mm) | 191 |
| AC Mode Efficiency Rating (100% Load) | 0.96 |
| Primary Form Factor | Tower |
| Nominal Input Voltage(s) Supported | 120 V AC |
| Low Voltage Transfer to Battery Power (Setpoint) | 89 |
| Voltage Regulation Description | Automatic voltage regulation (AVR) maintains line power operation with input voltage as low as 89 |
| Network UPS Tools Compatibility | NUT compatible. See the full list of Tripp Lite NUT compatible UPS systems at http://www.networkupstools.org/stable-hcl.html?manufacturer=Tripp Lite |
| Internal UPS Replacement Battery Cartridge | RBC51 |
| High Voltage Transfer to Battery Power (Setpoint) | 139 |
| Rated input current (Maximum Load) | 12A |
| Hot-Swap PDU options | PDUB15 (2U / 8 5-15R outlets) |
| Installation Form Factors Supported with Optional Accessories | Wallmount (UPSWM - tower mounting kit) |
| UPS AC Suppression Response Time | Instantaneous |
| WatchDog Compatibility | Supports Watchdog application, OS and hard-reboot restart options for remote applications |
| Communications Interface | USB (HID enabled) |
| LED Indicators | 4 LEDs indicate line power, battery power, overload and battery low/replace status |
| UPS Input Cord Length (ft.) | 6 |
| Alarm Cancel Operation | Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status |
| Storage Temperature Range | +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
| Battery Access | Battery access door |
| UPS Certifications | Meets FCC Part 15 Category B (EMI); Tested to CSA (Canada); Tested to NOM (Mexico); Tested to UL1778 (USA) |
| Input Phase | Single-Phase |
| AC Mode BTU / Hr. (Full Load) | 24 |
| Output kVA Capacity (kVA) | 1 |
| Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported |
| Communications Cable | USB interface cable included |
| Output Watt Capacity (Watts) | 500 |
| DC System Voltage (VDC) | 12 |
| Nominal Output Voltage(s) Supported | 110 V, 115 V, 120 V |
| Output AC Waveform (Battery Mode) | PWM sine wave |
| Audible Alarm | Audible alarm indicates power-failure and low-battery conditions |
| UPS AC Suppression Joule Rating | 510 |
| Output Volt Amp Capacity (VA) | 1,000 |
| Relative Humidity | 0 to 95%, non-condensing |
| EMI / RFI AC Noise Suppression | Yes |
| Battery Mode BTU / Hr. (Full Load) | 664 |
| Half Load Runtime (min.) | 14 min |
| Installation Form Factors Supported with Included Accessories | Tower |
| Expandable Runtime | No |
| UPS Power Module Dimensions (hwd, in.) | 10.8 x 5.2 x 7.5 |
| Battery Recharge Rate (Included Batteries) | Less than 4.5 hours from 10% to 90% |
| Recommended Electrical Service | 15A 120V |
| Typical Battery Recharge Time | 4 hr |
| Assembly Required | No |
| USB | Yes |
| Dataline Protection | RJ-45 |
| Maximum Operating Temperature | 122°F |
| Battery Chemistry | Valve Regulated Lead Acid |
| Form Factor | Tower |
| Surge Energy Rating | 480 J |
| Additional Information | The full load runtime is 3.5 minutes. Half load runtime is 14 minutes. |
| Protection Type | Surge |
| Status Indicators | 4 front panel LEDs indicate line power status, battery power status, battery low/replace status and voltage regulation operation |
| Waveform Type | Pulse-width Modulated Sine Wave |
| Load Capacity | 1000 VA/500 W |
| Package Contents | OMNIVS1000 Line Interactive UPS, USB and telephone cable, User manual with warranty information |
| Alarm | On Battery |
| Product Series | VS |
| Battery Life | 6 yr |
| Product Compliance | FCC Part 15 Class B (USA) |
| UPS Applications | Home/Office Desktop; High-End Desktop/Small Network; Retail/Point of Sale; Hospitality |
| Output Capacity (Watts) | 500 |
| Output Capacity (VA) | 1,000 |
| Product Certifications | CSA (Canada); NOM (Mexico); UL 1778 |
| Package Includes | OMNIVS1000 Line Interactive UPS;USB and telephone cable;User manual with warranty information |
| Operating Temperature - Maximum | 104 deg F |
| Data Line Protection | Includes Data Line Surge Protection |
| Includes Battery | Battery Included |
| Frequency | 60 Hz |
| Replacement Battery Part Number | RBC51 |
| Operating Temperature - Minimum | 32 deg F |
| Automatic Voltage Regulation | Includes Automatic Voltage Regulation |
| Power Cord Length | 6 ft |
| Receptacle Configuration | 5-15R |
| Manufacturer Warranty | 3 yr (Limited) |
| Audible Alarm Conditions | Low Battery |
| Input Current - Maximum | 12 A |
| Power Rating - Real | 500 W |
| Output Ports Included | USB |
| Visible Indicator Light Conditions | Battery Low, Overload, Power Status, Replace Battery |
| Number of Outlets - Surge Only | 2 |
| External Battery Compatible | Not External Battery Pack Compatible |
| Overall Depth | 7-1/2 in |
| Battery Recharge Time | 4 hr 30 min |
| Package Quantity | 1 |