UPS System, 450VA, Line Interactive, Out: 110/115/120V In: 120V AC
| Item | UPS System |
|---|---|
| UPS Type | Line Interactive |
| Power Rating | 450 VA |
| Mounting | Tower |
| Wattage | 240 W |
| Input Voltage | 120V AC |
| Output Voltage | 110/115/120V |
| Backup Time (Half/Full Load) | 5 min/0.5 min |
| Outlet Type | (3) Surge; (3) UPS/Surge |
| Number of Outlets | 4 |
| NEMA Receptacle Configuration | 5-15R |
| Width | 11.8 in |
| Transfer Time | 6 milliseconds |
| NEMA Plug Configuration | 5-15P |
| Hz | 60 Hz |
| Housing Material | ABS |
| Operating Temperature Range | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
| UPS Certifications | Meets FCC Part 15 Category A (EMI); Tested to CSA (Canada); Tested to NOM (Mexico); Tested to UL1778 (USA) |
| Relative Humidity | 0 to 90%, non-condensing |
| Battery Recharge Rate (Included Batteries) | 8 hours (10% to 90%) |
| Audible Alarm | Audible alarm indicates low-battery, fault, overload and replace-battery status |
| DC System Voltage (VDC) | 12 |
| Low Voltage Transfer to Battery Power (Setpoint) | 89 |
| Output Volt Amp Capacity (VA) | 450 |
| UPS Dataline Suppression | N/A |
| Output Voltage Regulation (Line Mode) | 120V |
| High Voltage Transfer to Battery Power (Setpoint) | 145 |
| UPS Certification Details | UL1778: 2014 5th EDITION; CAN/CSA-C22.2 NO. 107.3:2014 3rd EDITION; |
| Individually Controllable Load Banks | No |
| AC Mode Efficiency Rating (100% Load) | 0.95 |
| Output AC Waveform (Battery Mode) | PWM sine wave |
| Expandable Runtime | No |
| Input Phase | Single-Phase |
| Output Voltage Regulation (Battery Mode) | 120V (+/- 10%) |
| Primary Form Factor | Tower |
| UPS AC Suppression Joule Rating | 316 |
| AC Mode BTU / Hr. (Full Load) | 23 |
| Output Watt Capacity (Watts) | 240 |
| UPS Power Module Dimensions (hwd, in.) | 5.6 x 4 x 11.8 |
| Half Load Runtime (min.) | 5 min |
| Switches | Controls off/on power status |
| EMI / RFI AC Noise Suppression | Yes |
| Nominal Input Voltage(s) Supported | 120 V AC |
| Primary UPS Height (mm) | 142 |
| Undervoltage Correction | Input voltages between 89 and 108 are boosted by 18% |
| LED Indicators | 3 LEDs indicate online mode (green), battery mode (yellow) and fault mode (red) |
| Rated input current (Maximum Load) | 5A |
| Overvoltage Correction | Input voltages between 132 and 145 are reduced by 15% |
| UPS AC Suppression Response Time | Instantaneous |
| Installation Form Factors Supported with Included Accessories | Tower |
| Storage Temperature Range | to +45 degrees Celsius |
| Voltage Regulation Description | Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 89 to 145 |
| Recommended Electrical Service | 15A 120V |
| Communications Interface | None |
| UPS Input Cord Length (ft.) | 5 |
| Primary UPS Depth (mm) | 300 |
| Nominal Output Voltage(s) Supported | 110 V, 115 V, 120 V |
| Package Quantity | 1 |