| Item | UPS System |
|---|---|
| UPS Type | Standby |
| Power Rating | 550 VA |
| Mounting | Desktop, Wall |
| Wattage | 300 W |
| Input Voltage | 120V AC |
| Output Voltage | 110/115/120V |
| Backup Time (Half/Full Load) | 5 min/1.2 min |
| Outlet Type | (5) Surge; (5) UPS/Surge |
| Number of Outlets | 10 |
| Height | 3.1 in |
| Depth | 5.7 in |
| Width | 5.7 in |
| Full Load Runtime (min.) | 1 min 12 sec |
| Half Load Runtime (min.) | 5 min |
| Relative Humidity | 0 to 90%, non-condensing |
| Operating Elevation (ft.) | Up to 10,000 ft. |
| Operating Temperature Range | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
| Output Voltage Regulation (Line Mode) | 120V |
| UPS Input Cord Length (ft.) | 5 |
| High Voltage Transfer to Battery Power (Setpoint) | 145 |
| UPS Power Module Dimensions (hwd, in.) | 4.13 x 4.33 x 7.28 |
| UPS AC Suppression Joule Rating | 316 |
| Output Voltage Regulation (Battery Mode) | 120V (±10%) |
| Communications Cable | USB interface cable included |
| WatchDog Compatibility | Supports Watchdog application, OS and hard-reboot restart options for remote applications |
| Input Phase | Single-Phase |
| PowerAlert Software | For local monitoring via the UPS™s built-in USB port, download PowerAlert Local software at http://www.tripplite.com/poweralert |
| Audible Alarm | UPS remains silent in battery backup mode; Alarm sounds only to report low-battery, fault, overload and replace-battery conditions |
| UPS Dataline Suppression | 1 line TEL/DSL or Ethernet |
| Recommended Electrical Service | 15A 120V |
| Expandable Runtime | No |
| Switches | Switch controls power off/on status |
| Low Voltage Transfer to Battery Power (Setpoint) | 95 |
| Communications Interface | USB (HID enabled) |
| Battery Replacement Description | Replaceable internal batteries (see manual) |
| Rated input current (Maximum Load) | 6 A |
| Battery Access | Battery access door |
| Output Volt Amp Capacity (VA) | 550 |
| Green Energy-Saving Features | Greater than 95% efficiency - GREEN UPS |
| Nominal Input Voltage(s) Supported | 120 V AC |
| Storage Temperature Range | to +45 degrees Celsius |
| Primary UPS Height (mm) | 105 |
| DC System Voltage (VDC) | 12 |
| Battery Recharge Rate (Included Batteries) | 6.5 hours (10% to 90%) |
| Input Circuit Breakers | 7A |
| Nominal Output Voltage(s) Supported | 110 V, 115 V, 120 V |
| LED Indicators | 1 Status LED reports operating mode and fault status |
| AC Mode BTU / Hr. (Full Load) | 13.1 |
| Primary Form Factor | Desktop |
| Transfer Time | 6 milliseconds typical (10 milliseconds max) |
| Installation Form Factors Supported with Included Accessories | Tower; Ultra-compact desktop; Wallmount |
| UPS AC Suppression Response Time | Instantaneous |
| Primary UPS Depth (mm) | 185 |
| EMI / RFI AC Noise Suppression | Yes |
| UPS Certification Details | UL1778: 2014 5th EDITION; CAN/CSA-C22.2 NO. 107.3:2014 3rd EDITION; FCC CLASS B; FCC Part 68 Approved (#5WSWP01B005); Industry Canada Approved (#3449A-005, REN0.1B); RETIE (Colombia) |
| Output Watt Capacity (Watts) | 300 |
| High Availability UPS Features | Battery Independent Restart |
| Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported |
| AC Mode Efficiency Rating (100% Load) | >98% |
| UPS Certifications | Meets FCC Part 15 Category B (EMI); Tested to CSA (Canada); Tested to NOM (Mexico); Tested to UL1778 (USA) |
| Output AC Waveform (Battery Mode) | PWM sine wave |
| Product Compliance | FCC Part 15 Class B (USA); FCC Part 68 |
| Package Includes | INTERNET550U 550VA 300W 120V Standby UPS with 10 Outlets;USB cable;Owner's manual |
| Unit Dimensions (hwd / in.) | 4.13 x 4.33 x 7.28 |
| Product Certifications | CAN/CSA-C22.2 No. 107.3 (Canada); NOM (Mexico); RETIE (Colombia); UL 1778 |
| UPS Applications | Computer/Peripherals; Retail/Point of Sale; Hospitality |
| Output Capacity (VA) | 550 |
| Output Capacity (Watts) | 300 |
| Internal UPS Replacement Battery Cartridge | IMPORTANT BATTERY REPLACEMENT INFORMATION > If your INTERNET550U has no battery access door, please contact a local electronics repair technician to source and install a matching replacement battery; If your INTERNET550U UPS does have a battery replacement door and the original battery inside has a rating of 12V 3.6AH, please order Tripp Lite replacement battery Model Number RBC36H |
| Battery Type | VRLA |
| NEMA Plug Configuration | 5-15P |
| NEMA Receptacle Configuration | 5-15R |
| Hz | 50/60 Hz |
| Housing Material | ABS |
| Package Quantity | 1 |