| Item | UPS System |
|---|---|
| UPS Type | Line Interactive |
| Power Rating | 700 VA |
| Mounting | Tower, Wall |
| Wattage | 450 W |
| Input Voltage | 120V AC |
| Output Voltage | 115/120V AC |
| Backup Time (Half/Full Load) | 42 min/18 min |
| Outlet Type | UPS/Surge |
| Medical Grade | Yes |
| Number of Outlets | 4 |
| Footnotes | 3,4,14 |
| Green Environmental Attribute | Product Contributes To Reducing Energy Consumption |
| Fax/Modem Line Protection | No |
| Depth | 9 in |
| Height | 13 in |
| Hz | 60 Hz |
| NEMA Plug Configuration | 5-15P |
| Includes | 6 ft DB9 Serial Monitoring Cable, 6 ft USB Monitoring Cable, SMART700HG 700VA/450W Medical-Grade Tower UPS System |
| Ports | DB9 Serial, USB |
| NEMA Receptacle Configuration | 5-15R |
| Width | 9 in |
| Transfer Time | 2 to 4 msec |
| Cord Length | 6 ft |
| VA Rating - UPS Systems | 700 VA |
| Automatic Volts Regulation | Yes |
| Phase | Single |
| Display Type | LED |
| Input Current | 5.5 A |
| Special Features | AVR Corrects Brownouts and Overvoltages, Power Management Software, Pure Sine Wave Output |
| Standards | CSA (Canada), FCC Part 15 Class a (USA), RoHS, UL 60601-1, UL1778 |
| Voltage | 120 |
| Overall Width | 7-1/2 in |
| Battery Type | Sealed Lead Acid |
| Operating Temp. Range | 104°F (40°C) |
| Capacity - Batteries | 700 VA/450 W |
| Input Connection | 6 ft Cord with NEMA 5-15P-HG Plug |
| Housing Material | PVC |
| Severe Undervoltage Correction | Input voltages between 81 and 95 are boosted by 21% |
| Low Voltage Transfer to Battery Power (Setpoint) | 81 |
| Leakage Current | Equal to 100 microamps |
| Network Monitoring Port Description | Supports detailed monitoring of UPS and site power conditions |
| Output Volt Amp Capacity (VA) | 700 |
| Input Cord Length (ft.) | 6 |
| Output Voltage Regulation (Battery Mode) | 115V (+/- 5%) |
| PowerAlert Software | For local monitoring via the UPSâ„¢s built-in communication ports , download PowerAlert Local software at http://www.tripplite.com/poweralert |
| Full Load Runtime (min.) | 18 min |
| Relative Humidity | 0 to 95%, non-condensing |
| AC Suppression Joule Rating | 480 |
| Output Receptacle Details | Hospital grade output receptacles |
| AC Mode Efficiency Rating (100% Load) | 0.94 |
| Output Voltage Regulation (Line Mode) | -18% +8% |
| Individually Controllable Load Banks | No |
| Primary UPS Depth (mm) | 229 |
| Rated input current (Maximum Load) | 5.5 A |
| AC Suppression Response Time | Instantaneous |
| Output Isolation Transformer | Hospital grade load isolation transformer |
| Input Phase | Single-Phase |
| UPS Certifications | Meets FCC Part 15 Category A (EMI); Tested to CSA (Canada); Tested to UL1778 (USA); Tested to UL60601-1 (medical grade) |
| UPS Power Module Dimensions (hwd, in.) | 12.8 x 7.5 x 9 |
| DC System Voltage (VDC) | 36 |
| Nominal Input Voltage(s) Supported | 120 V AC |
| Alarm Cancel Operation | Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status |
| Recommended Electrical Service | 15A 120V |
| Expandable Runtime | No |
| Audible Alarm | Audible alarm indicates power-failure, overload and low-battery conditions |
| Primary Form Factor | Tower |
| Installation Form Factors Supported with Optional Accessories | Wallmount (UPSWM - tower mounting kit) |
| UPS AC Suppression Joule Rating | 480 |
| UPS AC Suppression Response Time | Instantaneous |
| High Availability UPS Features | Hot swappable batteries |
| Communications Interface | USB; DB9 Serial |
| AC Mode BTU / Hr. (Full Load) | 97.7 |
| Output AC Waveform (Battery Mode) | PWM sine wave |
| Overvoltage Correction | Input voltages between 126 and 143 are reduced by 9% |
| Switches | 2 Switches control off/on power status and alarm-cancel/self-test operation |
| Operating Temperature Range | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
| Storage Temperature Range | +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
| Output Watt Capacity (Watts) | 450 |
| Communications Cable | USB and DB9 serial cabling included |
| High Voltage Transfer to Battery Power (Setpoint) | 143 |
| Nominal Output Voltage(s) Supported | 115 V, 120 V |
| Voltage Regulation Description | Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 81 to 143 |
| Input Circuit Breakers | 10A |
| Cooling Method | Fan |
| Primary UPS Height (mm) | 325 |
| Battery Replacement Description | Hot-swappable, user replaceable batteries |
| Battery Access | Battery access door |
| UPS Input Cord Length (ft.) | 6 |
| Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported |
| EMI / RFI AC Noise Suppression | Yes |
| Undervoltage Correction | Input voltages between 96 and 106 are boosted by 10% |
| Grounding Lug | Grounding lug |
| Power Factor | 0.6 |
| Half Load Runtime (min.) | 42 min |
| Battery Mode BTU / Hr. (Full Load) | 189.1 |
| Battery Recharge Rate (Included Batteries) | Less than 4 hours from 10% to 90% |
| LED Indicators | 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status |
| Internal UPS Replacement Battery Cartridge | RBC36SLT |
| Form Factor | Tower |
| Network Management | SNMP Manageable |
| USB | Yes |
| Package Contents | SmartPro 700HG UPS, SMART 700HG Medical Grade UPS System, One USB and One DB9 monitoring cable, Warranty information, Instruction manual |
| Maximum Operating Temperature | 104°F |
| Battery Life | 6 yr |
| Load Capacity | 700 VA/450 W |
| Status Indicators | 5 front-panel indicator LEDs to show battery charge level, AC line voltage levels, automatic voltage regulation status, UPS load level and replace battery warning |
| Alarm | Overload, On Battery, Low Battery |
| Hot Swappable | Yes |
| Typical Battery Recharge Time | 4 hr |
| Additional Information | Ideal UPS protection for applications in medical patient-care areas where UL2601-1 listed medical electrical equipment is required, Maintains less than 300 microamps leakage current for UPS and all connected equipment, Built-in isolation transformer with faraday shield offers full isolation and removes common mode noise while maintaining full AC surge suppression in all modes, Line-interactive voltage regulation corrects brownouts and overvoltages from 81 to 143 volts back to usable 120V output levels, without using battery power, Hospital-grade plug and outlets offer added degree of safety and reliability to input/output connections, Full line isolation offers a higher degree of safety and prevents operational problems in sensitive electronic equipment, Resistant to electrostatic discharge, Supports loads up to 700VA / 450 watts, 42 minutes half load runtime (with 350VA load), 18 minutes full load runtime (with 700VA load), 4 protected hospital-grade outlets; 6-ft. cord, RS-232 and USB monitoring ports for remote monitoring and unattended shutdown, SNMP compatible with separate purchase SNMPWEBSOLO ethernet adapter accessory, PowerAlert unattended shutdown software available via free download from www.tripplite.com (cabling included), Complete surge protection, line isolation and EMI/RFI noise filtering, 2 year product warranty, 5 diagnostic LEDs indicate AC present, on battery, voltage correction, overload & battery low/replace, Battery replacement door, Grounding lug |
| Input Current - Maximum | 5.5 A |
| Operating Temperature - Maximum | 104 deg F |
| Data Line Protection | Includes Data Line Surge Protection |
| Includes Battery | Battery Included |
| Battery Recharge Time | 4 hr |
| Surge Suppression Rating | 480 J |
| Output Ports Included | DB9 Serial, USB |
| Automatic Voltage Regulation | Includes Automatic Voltage Regulation |
| Audible Alarm Conditions | Low Battery, Overload |
| External Battery Compatible | Not External Battery Pack Compatible |
| Power Rating - Real | 450 W |
| Operating Temperature - Minimum | 32 deg F |
| Manufacturer Warranty | 2 yr |
| Power Cord Length | 6 ft |
| Package Quantity | 1 |