UPS System, 700VA, Line Interactive, Out: 115/120V In: 120V AC
| Item |
UPS System |
| UPS Type |
Line Interactive |
| Power Rating |
700 VA |
| Mounting |
Tower, Wall |
| Wattage |
450 W |
| Input Voltage |
120V AC |
| Output Voltage |
115/120V |
| Backup Time (Half/Full Load) |
42 min/18 min |
| Medical Grade |
Yes |
| Number of Outlets |
4 |
| Transfer Time |
2-4 milliseconds |
| NEMA Plug Configuration |
5-15P |
| Housing Material |
PVC |
| Width |
9 in |
| Hz |
60 Hz |
| NEMA Receptacle Configuration |
5-15R |
| Primary UPS Height (mm) |
325 |
| AC Mode BTU / Hr. (Full Load) |
97.7 |
| Relative Humidity |
0 to 95%, non-condensing |
| Alarm Cancel Operation |
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status |
| Output Isolation Transformer |
Hospital grade load isolation transformer |
| Low Voltage Transfer to Battery Power (Setpoint) |
81 |
| Battery Replacement Description |
Hot-swappable, user replaceable batteries |
| Battery Access |
Battery access door |
| Output Volt Amp Capacity (VA) |
700 |
| Grounding Lug |
Grounding lug |
| Output Voltage Regulation (Line Mode) |
-18% +8% |
| Voltage Regulation Description |
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 81 to 143 |
| Battery Mode BTU / Hr. (Full Load) |
189.1 |
| Output Voltage Regulation (Battery Mode) |
115V (+/- 5%) |
| Full Load Runtime (min.) |
18 min |
| LED Indicators |
5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status |
| UPS Power Module Dimensions (hwd, in.) |
12.8 x 7.5 x 9 |
| Communications Cable |
USB and DB9 serial cabling included |
| AC Suppression Joule Rating |
480 |
| UPS Input Cord Length (ft.) |
6 |
| Operating Temperature Range |
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
| DC System Voltage (VDC) |
36 |
| Cooling Method |
Fan |
| UPS Certifications |
Meets FCC Part 15 Category A (EMI); Tested to CSA (Canada); Tested to UL1778 (USA); Tested to UL60601-1 (medical grade) |
| Nominal Output Voltage(s) Supported |
115 V, 120 V |
| Network Monitoring Port Description |
Supports detailed monitoring of UPS and site power conditions |
| Input Phase |
Single-Phase |
| Cold Start (Startup in Battery Mode During a Power Failure) |
Cold-start operation supported |
| Severe Undervoltage Correction |
Input voltages between 81 and 95 are boosted by 21% |
| High Voltage Transfer to Battery Power (Setpoint) |
143 |
| Audible Alarm |
Audible alarm indicates power-failure, overload and low-battery conditions |
| Input Circuit Breakers |
10A |
| Leakage Current |
Equal to 100 microamps |
| Internal UPS Replacement Battery Cartridge |
RBC36SLT |
| Switches |
2 Switches control off/on power status and alarm-cancel/self-test operation |
| EMI / RFI AC Noise Suppression |
Yes |
| Expandable Runtime |
No |
| Installation Form Factors Supported with Optional Accessories |
Wallmount (UPSWM - tower mounting kit) |
| Rated input current (Maximum Load) |
5.5 A |
| Input Cord Length (ft.) |
6 |
| Overvoltage Correction |
Input voltages between 126 and 143 are reduced by 9% |
| Nominal Input Voltage(s) Supported |
120 V AC |
| UPS AC Suppression Response Time |
Instantaneous |
| Output Watt Capacity (Watts) |
450 |
| AC Mode Efficiency Rating (100% Load) |
0.94 |
| Undervoltage Correction |
Input voltages between 96 and 106 are boosted by 10% |
| Power Factor |
0.6 |
| Output Receptacle Details |
Hospital grade output receptacles |
| Recommended Electrical Service |
15A 120V |
| High Availability UPS Features |
Hot swappable batteries |
| AC Suppression Response Time |
Instantaneous |
| Storage Temperature Range |
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
| Battery Recharge Rate (Included Batteries) |
Less than 4 hours from 10% to 90% |
| Output AC Waveform (Battery Mode) |
PWM sine wave |
| PowerAlert Software |
For local monitoring via the UPS™s built-in communication ports , download PowerAlert Local software at http://www.tripplite.com/poweralert |
| Primary Form Factor |
Tower |
| Half Load Runtime (min.) |
42 min |
| Communications Interface |
USB; DB9 Serial |
| Individually Controllable Load Banks |
No |
| UPS AC Suppression Joule Rating |
480 |
| Primary UPS Depth (mm) |
229 |
| Package Quantity |
1 |