| Item | UPS System |
|---|---|
| Number of Outlets | 12 |
| Voltage | 120 |
| Cord Length | 6 ft |
| Housing Material | ABS |
| NEMA Receptacle Configuration | 5-15R |
| NEMA Plug Configuration | 5-15p |
| Watts | 450W |
| Display Type | No Display |
| Special Features | (4) Built-In ECO Outlets w/Auto Off, Poweralert Software |
| Output Voltage | 110 V, 115 V, 120 V |
| Height | 3 in |
| UPS Type | Standby |
| Input Current | 10 A |
| Depth | 7 in |
| Outlet Type - UPS Systems | Surge, UPS |
| Width | 12 in |
| Output Voltage - UPS Systems | 115V AC, 120V AC |
| Mounting - UPS Systems | Desktop/Tower |
| Automatic Volts Regulation | No |
| Footnotes | 4,6 |
| Fax/Modem Line Protection | Yes |
| Mounting | Desktop, Tower, Wall |
| Standards | CSA, FCC Part 15 Class B, NOM, RoHS, UL1778 |
| Includes | USB Cables |
| Hz | 60 Hz |
| Power Rating | 750 VA |
| Input Voltage | 120 V AC |
| Backup Time (Half/Full Load) | 11.5 min/2.5 min |
| Ports | USB |
| Medical Grade | Not Medical Grade Approved |
| Transfer Time | 3 msec from Battery to AC, 6 msec from AC to Battery |
| VA Rating - UPS Systems | 750 VA |
| Phase | Single |
| Input Voltage - UPS Systems | 120V AC |
| Green Environmental Attribute | Product Contributes To Reducing Energy Consumption |
| Watts - UPS Systems | 450 W |
| Outlet Type | Surge, UPS |
| Green Certification or Other Recognition | UL Listed Certification, RoHS |
| Wattage | 450 W |
| Overall Width | 5.12 in |
| Overall Height | 3.35 in |
| Operating Temp. Range | 104°F (40°C) |
| Backup/Run Time (Full Load) | 2 Minute/8.60 Minute |
| For Use with | Security System, Router, TV, ATM, Gaming Console, Digital Signage, Computer, Blu-ray Player, Kiosk, Business, Printer |
| Capacity - Batteries | 750 VA/450 W |
| Input Connection | 6 ft Cord with NEMA 5-15P Plug |
| Battery Type | Valve Regulated Lead Acid (VRLA) |
| Primary UPS Height (mm) | 85 |
| DC System Voltage (VDC) | 12 |
| UPS Housing Material | ABS |
| Primary UPS Depth (mm) | 310 |
| Expandable Runtime | No |
| UPS AC Suppression Response Time | Instantaneous |
| Primary Form Factor | Desktop |
| Frequency Compatibility | 50 / 60 Hz |
| High Voltage Transfer to Battery Power (Setpoint) | 145 |
| Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported |
| UPS Dataline Suppression | 1 line TEL/DSL or Ethernet |
| Load Management Receptacles | The ECO Energy-Saving option will automatically POWER OFF four designated ECO outlets when the device connected to the MASTER load-sensing outlet is turned off (after approximately 3 minutes); ECO outlets will immediately POWER ON when the device connected to the MASTER load-sensing outlet begins consuming 23 watts or more (see manual) |
| Input Phase | Single-Phase |
| AC Mode Efficiency Rating (100% Load) | >98% |
| Rated input current (Maximum Load) | 10 A |
| Audible Alarm | UPS remains silent in battery backup mode; Alarm sounds only to report low-battery, fault, overload and replace-battery conditions |
| High Availability UPS Features | Battery Independent Restart |
| PowerAlert Software | For local monitoring via the UPS™s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert |
| Storage Temperature Range | +5 to +113 degrees Fahrenheit / -15 to +45 degrees Celsius |
| Internal UPS Replacement Battery Cartridge | RBC51 |
| Output AC Waveform (Battery Mode) | PWM sine wave |
| Primary UPS Width (mm) | 130 |
| UPS Input Cord Length (ft.) | 5 |
| UPS Certification Details | UL1778: 2014 5th EDITION; CAN/CSA-C22.2 NO. 107.3:2014 3rd EDITION; FCC CLASS B; FCC Part 68 Approved (#5WSWP01B005); Industry Canada Approved (#3449A-005, REN0.1B); RETIE (Colombia) |
| Operating Temperature Range | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
| Recommended Electrical Service | 15A 120V |
| UPS Power Module Dimensions (hwd, in.) | 3.35 x 5.12 x 12.2 |
| Nominal Output Voltage(s) Supported | 110V, 115V, 120V |
| Half Load Runtime (min.) | 8 min 36 sec |
| Output Volt Amp Capacity (VA) | 750 |
| WatchDog Compatibility | Supports Watchdog application, OS and hard-reboot restart options for remote applications |
| Low Voltage Transfer to Battery Power (Setpoint) | 95 |
| Output Voltage Regulation (Battery Mode) | 120V (±10%) |
| UPS Input Connection Type | 5-15P |
| Communications Cable | USB interface cable included |
| Battery Access | Battery access door |
| Output AC Waveform (AC Mode) | Pure sine wave |
| Battery Replacement Description | Replaceable internal batteries (see manual) |
| Nominal Voltage Details | 120v nominal output in battery mode |
| UPS AC Suppression Joule Rating | 316 |
| UPS Certifications | ENERGY STAR Qualified; Meets FCC Part 15 Category B (EMI); Tested to CSA (Canada); Tested to NOM (Mexico); Tested to UL1778 (USA) |
| Output Receptacles | 5-15R |
| LED Indicators | 3 Status LEDs; GREEN #1 LED reports ECO mode off/on status; GREEN #2 LED reports line/battery mode operation, low-battery condition, overload and replace-battery notifications; RED LED reports battery-low, overload, replace-battery and fault conditions (see manual) |
| Communications Interface | USB |
| Nominal Input Voltage(s) Supported | 120 V AC |
| Full Load Runtime (min.) | 2 min |
| Input Circuit Breakers | 10A |
| Installation Form Factors Supported with Included Accessories | Tower; Ultra-compact desktop; Wallmount |
| Battery Recharge Rate (Included Batteries) | 6.5 hours (10% to 90%) |
| Switches | Switch controls power off/on status and ECO mode off/on status |
| Output Voltage Regulation (Line Mode) | 120 V |
| Relative Humidity | 0 to 90%, non-condensing |
| Individually Controllable Load Banks | No |
| EMI / RFI AC Noise Suppression | Yes |
| UPS Output Receptacles (Surge Suppression Only) | 6 UPS outlets, 6 surge-only outlets |
| AC Mode BTU / Hr. (Full Load) | 8.3 |
| Operating Elevation (ft.) | Up to 10,000 ft. |
| Output Watt Capacity (Watts) | 450 |
| Storage Temperature | 5°F (-15°C) - 113°F (45°C) |
| Receptacle Detail | 12 x NEMA 5-15R |
| Plug/Connector Type | NEMA 5-15P |
| Assembly Required | No |
| EMI/RFI Noise Filter | Yes |
| Application/Usage | Computer, Gaming Console, Security System, Printer, TV, ATM, Blu-ray Player, Business, Digital Signage, Kiosk, Router |
| Package Contents | ECO 750VA Desktop UPS, Owner's Manual, USB Cable |
| Product Type | Standby UPS |
| DC System Voltage | 12 V DC |
| Product Series | ECO |
| Energy Saving | Greater than 95% efficiency - GREEN UPS; Power saving auto-shutoff ECO outlets |
| Replaceable Battery | Yes |
| Number of Battery & Surge Outlets | 6 |
| Certifications & Standards | UL Listed Certification |
| Form Factor | Tower, Desktop, Wall Mount |
| Status Indicators | 3 Status LEDs; GREEN #1 LED reports ECO mode off/on status; GREEN #2 LED reports line/battery mode operation, low-battery condition, overload and replace-battery notifications; RED LED reports battery-low, overload, replace-battery and fault conditions |
| Number of Surge-only Outlets | 6 |
| Output Frequency | 60 Hz |
| Load Capacity | 750 VA/450 W |
| Input Frequency | 60 Hz |
| Typical Battery Recharge Time | 6 hr 30 min |
| Maximum Operating Elevation | 10,000 ft |
| Backup/Run Time (Half Load) | 8 min 36 sec |
| Alarm | Replace Battery, Low Battery, Overload, Fault |
| Surge Energy Rating | 316 J |
| Dataline Protection | RJ-11, RJ-45 |
| Additional Information | 99% line-mode efficiency saves energy and operating costs, 4 built-in "ECO" outlets save power by automatically turning off connected accessories when the computer is not in use, Input cord length 6 ft / 1.8m, This product is ENERGY STAR qualified for its ability to save customers money while helping to protect the environment |
| USB | Yes |
| Product Name | ECO 750VA Desktop UPS |
| Maximum Operating Temperature | 104 deg F |
| USB (HID Compliant) Port | Yes |
| Waveform Type | Pure Sine Wave |
| Product Compliance | ENERGY STAR Qualified; FCC Part 15 Class B (USA) |
| Frequency Compatibility Details | Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal. |
| Package Includes | ECO750UPS 750VA 450W 120V Standby ECO UPS with 12 Outlets;USB cable;Owner's manual |
| Output Capacity Details | 6.3A @ 120V. (LINE MODE) 110%+/- 10% @ 5 minutes; (BATTERY MODE) 110% +/- 10% @ 5 seconds |
| Runtime Full Load (min.) | 2 min |
| Output Capacity (Watts) | 450 |
| Voltage Regulation Description | Input voltage range of 90 to 145 |
| Product Certifications | RETIE (Colombia); CSA (Canada); NOM (Mexico); UL 1778 |
| UPS Applications | Computer/Peripherals; Audio/Video; Retail/Point of Sale; Hospitality |
| Runtime Half Load (min.) | 8 min 36 sec |
| Output Capacity (VA) | 750 |
| Overall Depth | 12.2 in |
| Plug Configuration | 5-15P |
| Operating Temperature - Minimum | 32 Degrees F |
| Input Current - Maximum | 10 A |
| Receptacle Configuration | 5-15R |
| Output Ports Included | USB |
| Power Rating - Real | 450 W |
| Battery Chemistry | Valve Regulated Lead Acid |
| Visible Indicator Light Conditions | Battery Low, Overload, Replace Battery |
| Includes Battery | Battery Included |
| Manufacturer Warranty | 3 yr Limited |
| Audible Alarm Conditions | Low Battery, Overload, Replace Battery |
| Number of Outlets - Surge Only | 6 |
| Power Rating - Apparent | 750 VA |
| Data Line Protection | Includes Data Line Surge Protection |
| Power Cord Length | 5 ft |
| Run Time - Full Load | 2 min |
| Surge Suppression Rating | 316 J |
| Battery Recharge Time | 6 hr 30 min |
| Run Time - Half Load | 8 min 36 sec |
| Transfer Time - Maximum | 10 msec |
| Number of Outlets - UPS | 6 |
| External Battery Compatible | Not External Battery Pack Compatible |
| Operating Temperature - Maximum | 104 Degrees F |
| Automatic Voltage Regulation | No Automatic Voltage Regulation |
| Transfer Time - Minimum | 6 msec |
| Frequency | 50/60 Hz |
| Package Quantity | 1 |