Furnace Control Board
| Item | Replacement Control Board |
|---|---|
| Replaces | B18099-06, B18099-08, B18099-10, B1809913, CNT04664, Mfr. No. 50T35-730 |
| For Use With | Commercial HVAC Equipment, Residential |
| Input Voltage | 24V AC |
| Agency Compliance | CSA |
| Includes | ECMx Motor Control, PSC, Variable Speed |
| Type | OEM Replacement |
| Heat Blower On Delay Setting | 30 sec |
| Twinning Compatibility | Twinning Compatible |
| Board Type | Integrated |
| Control Voltage | 24 V |
| Minimum Operating Temperature | -40 deg F |
| Terminal Designations | G, R, W |
| Control Mounting Type | Standoff |
| Ignition Type | Hot Surface Igniter |
| Compatible with Brand | Goodman, Texas Instruments, UTEC, White-Rodgers |
| Connection Interface Type | Spade Terminal |
| Number of Speed Taps | 2 |
| Compatible Blower Motor Type | Permanent Split Capacitor |
| Standards | CSA Certified |
| OEM Replacement Part Number | 50T35-730, B18099-06, B18099-08, B18099-10, B1809913, B1809913S |
| Maximum Operating Temperature | 175 deg F |
| Maximum Relative Humidity | 93 % |
| Igniter Voltage | 120V AC |
| Cool Blower Off Delay Setting | 60 sec |
| Items Controlled | Air Cleaners, Blowers, Gas Valves, Humidifiers, Ignitors, Inducers |
| Product Type | Replacement Control Board |
| Heat Blower Off Delay Setting | 90 sec, 120 sec, 150 sec |
| Number of Stages | 1 |
| Cool Blower On Delay Setting | 5 sec |
| Minimum Relative Humidity | 5 % |
| Compatible Inducer Motor Type | Permanent Split Capacitor |
| Replacement Type | OEM |
| Furnace Control Functions | Heat, Cool |
| Country of Origin (subject to change) | Mexico |
| Package Quantity | 1 |