| Item | Digital Multimeter |
|---|---|
| Display Type | LCD |
| Data Hold | Yes |
| Instrument Counts | 3,999 |
| Includes | Battery, Holster with Magnetic Hanging Strap, Spare Fuse, Temperature Adapter, Test Leads with Threaded Alligator Clips, Type K Thermocouple |
| Standards | cCSAus, OSHA, UL |
| Auto Power Off | Yes |
| Data Logging | No |
| Audible Continuity | Yes |
| Diode Test | Yes |
| Calibration Certificate Included | No Certification Included |
| Max. DC Amps | 10 A |
| Temp. Range | -4 to 1,832 deg F |
| Max. Ohms | 4 megohm |
| Series | AMPROBE (R) 33XR-A |
| AC Response | TRMS |
| Instrument Safety Rating | CAT III 600V, CAT II 1000V |
| Manufacturers Warranty Length | 1 yr |
| Basic DC Accuracy | +/-0.70% of Reading + 1 Digit |
| Multimeter Style | Full Size - Basic Features |
| Capacitance Range | 4000 uF |
| Instrument Frequency Counter Range | 1 Hz to 40 Mhz |
| Peak Hold | Yes |
| Display | LCD |
| Max. AC Amps | 10:00 AM |
| Duty Cycle | Duty Cycle Test Included |
| Auto Ranging | Yes |
| Intrinsically Safe | No |
| Batteries Included | Yes |
| Basic AC Current Accuracy | +/- (1.5 % rdg + 4 dgts) |
| Maximum Temperature Measurement | 1,832 deg F |
| Minimum DC Voltage Measurement | 400 V |
| Frequency Measurement Accuracy | +/- (0.1 % rdg + 3 dgts) |
| Bluetooth Compatible | No |
| Battery Chemistry | Alkaline |
| Minimum Operating Temperature | 32 deg F |
| Current Leakage Testing | No |
| Temperature Measurement Accuracy | -20 Degrees C to 10 Degrees C +/- (2.0 % rdg + 4 Degrees C ) 10 Degrees C to 200 Degrees C +/- (1.0 % rdg + 3 Degrees C ) 200 Degrees C to 1000 Degrees C +/- (3.0 % rdg + 2 Degrees C ) -4 Degrees F to 50 Degrees F +/- (2.0 % rdg + 8 Degrees F) 50 Degrees F to 400 Degrees F +/- (1.0 % rdg + 6 Degrees F) 400 Degrees F to 1832 Degrees F +/- (3.0 % rdg + 4 Degrees F) |
| Basic DC Current Accuracy | +/- (1.0 % rdg + 1 dgt) |
| Maximum Operating Temperature | 113 deg F |
| Overall Width | 3.62 in |
| Thermal Imaging | No |
| AC Response Calculation | Average |
| Removable Screen | No |
| Maximum AC Voltage Measurement | 1,000 V |
| Capacitance Measurement Accuracy | +/- (5.0 % rdg + 5 dgts) |
| Basic AC Voltage Accuracy | +/- (1.5 % rdg + 4 dgts) |
| Maximum Capacitance Measurement | 4,000 uF |
| Frequency Measurement Resolution | 4 kHz |
| Fuse Access | Yes |
| Minimum DC Current Measurement | 400 uA |
| Minimum/Maximum Memory | Max, Min |
| Bar Graph Included | Yes |
| DC Current Measurement Resolution | 400 uA |
| AC Current Measurement Resolution | 400 uA |
| Battery Access | Yes |
| AC Voltage Measurement Resolution | 400 V |
| Temperature Measurement Resolution | 0 deg C |
| Capacitance Measurement Resolution | 4 uF |
| Overall Height | 7.71 in |
| Computer Interface Connection Type | None |
| Minimum Capacitance Measurement | 4 uF |
| Maximum Storage Temperature | 140 deg F |
| Minimum AC Voltage Measurement | 400 V |
| Battery Size | 9V |
| DC Voltage Measurement Resolution | 400 V |
| Maximum Frequency Measurement | 1 MHz |
| Minimum Resistance Measurement | 400 ohm |
| Maximum DC Voltage Measurement | 1,000 V |
| Weight | 0.9 lb |
| Maximum AC Current Measurement | 10 A |
| Parameters Measured | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature |
| Resistance Measurement Resolution | 400 ohms |
| Depth | 2.36 in |
| Minimum AC Current Measurement | 400 uA |
| Battery Voltage | 9 V |
| Minimum Frequency Measurement | 4 kHz |
| Dustproof | No |
| Resistance Measurement Accuracy | +/-1.2% |
| Waterproof | No |
| Minimum Storage Temperature | -4 deg F |
| Minimum Temperature Measurement | -4 deg F |
| Maximum DC Current Measurement | 10 A |
| Basic DC Voltage Accuracy | +/-0.70% + 1 Digit |
| Maximum Resistance Measurement | 4 megaohm |
| Data Output Type | Not Applicable |
| Special Features | Analog Bar Graph, Auto Power Off to Save Battery Life, Display Update Rate: 2/sec, Nominal, Display: 3-3/4 Digit LCD, 3999 Counts with 41-Segment Analog Bar Graph, Input Warning Tone When Test Leads are in Wrong Jack, Magne-Grip(TM) Holster with Magnetic Hanging Strap, Min/Max, Relative, Peak and Data Hold, Operating Temperature: 0 Degrees C to 45 Degrees C at Less Than70% R.H, Overrange Indication, Separate Door for Easy Battery and Fuse Access, Storage Temperature: -20 Degrees C to 60 Degrees C |
| Current Units | A, mA |
| IP Rating | Not Rated |
| Temperature Types Measured | Not Applicable |
| CAT Safety Rating | CAT II 1000V, CAT III 600V |
| Voltage Units | Not Applicable |
| Includes Auto Sensing | No Auto Sensing Included |
| Country of Origin (subject to change) | Taiwan, Province of China |
| Package Quantity | 1 |