| For Media | Aggressive Gases, Aggressive Liquids, Air, Ammonia, Biodiesel Fuel, Cryogenic Fluids, Fuel Oil, Hot Water, Inert Gases, Light Oil, Liquid Propane Gas, Natural Gas, Oxygen, Steam, Water |
|---|---|
| Valve Ways | 2-Way |
| Valve Starting Configuration | Normally Closed |
| Nominal Pipe Size | 1/8 in |
| Inlet Connection Type | NPTF |
| Outlet Connection Type | NPTF |
| Voltage | 12V DC |
| Valve Type | High Flow |
| Operation Type | Direct Acting |
| Seal Material | NBR |
| Operating Pressure Differential - Maximum | 130 psi Air/Inert Gas, 95 psi Light Oil, 110 psi Water |
| Operating Pressure Differential - Minimum | 0 psi |
| Item | Solenoid Valve |
| IP Rating | IP65 |
| Coil Enclosure | H |
| Body Material | Brass |
| Overall Length | 1-1/4 in |
| Compliance | CSA, UL |
| Overall Height | 2-27/32 in |
| Standards | CE, CSA, FM, UL Listed |
| Electrical Connections | 16 in Leads |
| Valve Design | 2-Position, 2-Way |
| Overall Width | 1-11/16 in |
| Center Line Pipe Center Size | 2-31/64 in |
| Coil Insulation Class | H |
| Application | Boilers, Burners, Car Wash Equipment, Compressors, Dishwashing and Laundry Equipment, Food Processing, Pumps |
| Operating Pressure Differential Fuel Oil - Minimum | Not Applicable |
| Operating Pressure Differential Cryogenic Fluid - Minimum | Not Applicable |
| Operating Pressure Differential Steam - Minimum | Not Applicable |
| Operating Pressure Differential Steam - Maximum | Not Rated |
| Operating Pressure Differential Air/Inert Gas - Minimum | 0 psi |
| Operating Pressure Differential Natural Gas - Minimum | Not Applicable |
| Fluid Temperature - Maximum | 180 deg F |
| Environmental Rating | Corrosive, Hazardous, Indoor, Outdoor |
| Operating Pressure Differential Fuel Oil - Maximum | Not Applicable |
| Operating Pressure Differential Light Oil - Maximum | 95 psi |
| Thread Type | NPT |
| Wattage | 10.6 W |
| Operating Pressure Differential Fuel Gas - Minimum | Not Applicable |
| Operating Pressure Differential Water - Maximum | 110 psi |
| Operating Pressure Differential Air/Inert Gas - Maximum | 130 psi |
| Operating Pressure Differential Cryogenic Fluid - Maximum | Not Applicable |
| Operating Pressure Differential Fuel Gas - Maximum | Not Applicable |
| Includes Coil | Yes |
| Operating Pressure Differential Hot Water - Maximum | Not Rated |
| Operating Pressure Differential Light Oil - Minimum | 0 psi |
| Operating Pressure Differential Hot Water - Minimum | Not Applicable |
| Orifice Diameter | 1/8 in |
| Operating Pressure Differential Liquid CO2 - Maximum | Not Applicable |
| Valve Positions | 2-Position |
| Operating Pressure Differential Water - Minimum | 0 psi |
| Response Time | 1 sec |
| Ambient Temperature - Maximum | 131 deg F |
| Ambient Temperature - Minimum | -13 deg F |
| Operating Pressure Differential Natural Gas - Maximum | Not Applicable |
| NEMA Enclosure Rating | 4X |
| Operating Pressure Differential Liquid CO2 - Minimum | Not Applicable |
| Includes Seal | Yes |
| Mounting Orientation | Vertical, Horizontal |
| Coefficient of Volume (Cv) | 0.35 |
| Wire Rope Length | 1-1/4 in |
| Length | 1-1/4 in |
| Country of Origin (subject to change) | United States |
| Package Quantity | 1 |