| For Media | Air, Inert Gases, Liquid Propane Gas, Natural Gas, Oxygen |
|---|---|
| Valve Ways | 2-Way |
| Valve Starting Configuration | Normally Closed |
| Nominal Pipe Size | 3/4 in |
| Inlet Connection Type | NPTF |
| Outlet Connection Type | NPTF |
| Voltage | 120V AC |
| Valve Type | Test Port |
| Operation Type | Pilot Operated |
| Seal Material | NBR |
| Operating Pressure Differential - Maximum | 5 psi |
| Operating Pressure Differential - Minimum | 0 psi |
| Item | Solenoid Valve |
| Application | Finishing, Low Gas Supply, Painting, Space Constrained |
| Body Material | Aluminum |
| Ambient Temp. Range | -40 Degrees to 125 Degrees F |
| Electrical Connections | 1/2 in Conduit |
| Overall Height | 4-15/16 in |
| Valve Design | 2-Position, 2-Way |
| Standards | CSA C/I, CSA C22.2, CSA Z21.21, FM, UL Listed |
| Overall Length | 3-5/16 in |
| Coil Insulation Class | F |
| Coil Enclosure | With Junction Box |
| BtuH | 247,500 |
| Overall Width | 2-3/8 in |
| Center Line Pipe Center Size | 3-21/32 in |
| Operating Pressure Differential Cryogenic Fluid - Maximum | Not Applicable |
| Valve Positions | 2-Position |
| Frequency | 60 Hz |
| Operating Pressure Differential Liquid CO2 - Maximum | Not Applicable |
| Operating Pressure Differential Fuel Gas - Minimum | 0 psi |
| Operating Pressure Differential Steam - Maximum | Not Rated |
| Operating Pressure Differential Liquid CO2 - Minimum | Not Applicable |
| Operating Pressure Differential Cryogenic Fluid - Minimum | Not Applicable |
| Coefficient of Volume (Cv) | 5.1 |
| Fluid Temperature - Maximum | 125 deg F |
| Operating Pressure Differential Air/Inert Gas - Maximum | 5 psi |
| Operating Pressure Differential Natural Gas - Maximum | Not Applicable |
| Ambient Temperature - Minimum | -40 deg F |
| Gas Capacity | 247,500 BtuH |
| Ambient Temperature - Maximum | 140 deg F |
| Operating Pressure Differential Hot Water - Minimum | Not Applicable |
| Operating Pressure Differential Fuel Oil - Maximum | Not Applicable |
| Operating Pressure Differential Fuel Oil - Minimum | Not Applicable |
| Operating Pressure Differential Hot Water - Maximum | Not Rated |
| Wattage | 17.1 W |
| Thread Type | NPT |
| Response Time | 1 sec |
| Orifice Diameter | 3/4 in |
| Operating Pressure Differential Light Oil - Minimum | Not Applicable |
| Operating Pressure Differential Fuel Gas - Maximum | 5 psi |
| Operating Pressure Differential Light Oil - Maximum | Not Rated |
| Actuator Type | Solenoid |
| Mounting Orientation | Vertical |
| Operating Pressure Differential Natural Gas - Minimum | Not Applicable |
| Includes Seal | Yes |
| Operating Pressure Differential Air/Inert Gas - Minimum | Not Applicable |
| NEMA Enclosure Rating | 4, 4X, 3, 3S, 1, 2 |
| Includes Coil | Yes |
| Environmental Rating | Hazardous, Indoor, Outdoor |
| Operating Pressure Differential Steam - Minimum | Not Applicable |
| Operating Pressure Differential Water - Maximum | 5 psi |
| Wire Rope Length | 3-5/16 in |
| Length | 3-5/16 in |
| Country of Origin (subject to change) | Mexico |
| Package Quantity | 1 |