| Item | Pressure Transmitter |
|---|---|
| Accuracy | +/-0.25% of Full Scale |
| Housing Material | Nylon |
| Output | 4 to 20mA DC |
| Electrical Connections | 4-Pin M12 Connector |
| Process Connection | 1/4 in Male NPT |
| Process Connection Type | NPT |
| Process Connection Size | 1/4 in |
| Operating Temp. | -40 Degrees to 257 Degrees F |
| Power Required | 9V DC to 36V DC |
| Response Time | 1 msec |
| Series | T2 |
| Operating Temp. - Transmitter | -40 to 257 deg F |
| Housing | Nylon |
| Thermal Error | +/-1% |
| Features | Proven Polysilicon Film Sensor |
| Transmitter Type | Pressure Transmitter |
| NEMA Rating | NEMA 4X |
| Accuracy - Transmitter | +/-0.25% Full Scale |
| Compatible With | Any Process Compatible with Stainless Steel |
| Range Values - Transmitter | 0 to 500 |
| Wetted Materials - Transmitters | Stainless Steel |
| Wiring Entry - Transmitter | None |
| Range | 0 to 500 psi |
| Process Connection Size - Transmitter | 1/4 in |
| Range Units - Transmitter | psi |
| Max. Pressure (PSI) | 1,000 psi |
| Loop Resistance | Dependent on Loop Supply Voltage |
| Includes | Instructions |
| Output - Transmitter | 4 to 20mA DC |
| Power Required - Transmitters | 9 to 36 V DC |
| Manufacturers Warranty Length | 1 yr |
| Process Connection Type - Transmitter | MNPT |
| Wetted Materials | Stainless Steel |
| Electrical Connections - Transmitter | Hirschmann Connector |
| Minimum Operating Temperature | -40 deg F |
| Minimum Pressure | 0 psi |
| Number of Wires | 2 |
| Fitting Material | Stainless Steel |
| Overpressure | 2x Range |
| Explosion/Fire Proof | No |
| Pressure Units | psi |
| Maximum Pressure | 500 psi |
| Standards | CE, RoHS, UL Recognized |
| Burst Pressure | 10x Range |
| IP Rating | IP66 |
| Maximum Operating Temperature | 257 deg F |
| Storage Temperature Range | -40 Degrees F to 257 Degrees F (-40 Degrees C to 125 Degrees C) |
| Overall Height | 3.45 in |
| Intrinsically Safe | No |
| Electrical Connection | 4-Pin M12 Connector |
| Process Connection Gender | Male |
| Wiring Entry | None |
| Overall Width | 1.06 in |
| Type of Pressure | Gauge |
| Includes NIST-Traceable Calibration Certificate | No NIST-Traceable Calibration Certificate Included |
| Hazardous Location Specification | Not Applicable |
| NEMA Enclosure Rating | 4X |
| Output Power | 4 to 20mA DC |
| Pressure Measurement - Minimum | 0 psi |
| Intrinsic Safety | Not Specified Intrinsically Safe |
| Process Media Temperature - Maximum | 257 deg F |
| Input Voltage | 9 to 36 V DC |
| Pressure Measurement - Maximum | 500 psi |
| Process Media Temperature - Minimum | -40 deg F |
| Pressure Type Measured | Gauge |
| Cable Length | Not Applicable |
| Fits Chest Size | Proven Polysilicon Film Sensor |
| Country of Origin (subject to change) | United States |
| Package Quantity | 1 |