| HP | 1/2 hp |
|---|---|
| Item | Centrifugal Pump |
| Housing Material | Noryl |
| Phase | Three |
| Voltage | 460V, 208V to 230V |
| Max. GPM @ Head | 26 gpm @ 10 ft |
| Max. Head | 68 ft |
| Inlet | 1-1/2 in NPT |
| Best Efficiency GPM @ Head | 20 gpm @ 35 ft |
| Outlet | 1-1/2 in NPT |
| Motor Enclosure | Totally Enclosed Fan Cooled |
| Max. Case Pressure | 100 psi |
| Port Rotation | None |
| Amps | 1.7-1.6/0.8 |
| Impeller Type | Closed |
| GPM of Water @ 50 Ft. of Head | 11 |
| GPM of Water @ 40 Ft. of Head | 14 |
| Width | 7-5/8 in |
| Wetted Materials | Carbon, Ceramic, Noryl, Viton |
| Min. GPM @ Head | 9 gpm @ 60 ft |
| Seal Material | Carbon, Ceramic, Noryl, Viton |
| Shaft Material | Stainless Steel |
| Inlet Pressure | 75 psi |
| Best Efficiency Range GPM @ Head | 11 to 20 gpm @ 50 to 28 ft |
| GPM of Water @ 15 Ft. of Head | 24 |
| Seal Type | Mechanical |
| GPM of Water @ 10 Ft. of Head | 26 |
| Drain Plug | Yes |
| Height | 7-1/2 in |
| Duty | Continuous |
| Max. Fluid Viscosity | 100 SUS |
| Volute Material | Noryl |
| Max. Liquid Temp. | 180 deg F |
| NEMA/IEC Frame | 56J |
| Manufacturers Warranty Length | 1 yr |
| GPM of Water @ 30 Ft. of Head | 19 |
| Max. Specific Gravity | 1 |
| Length | 15.8 in |
| Max. Dia. Solids | 1/4 in |
| Motor RPM | 3,450 rpm |
| Impeller Material | Noryl |
| Bearing Type | Ball |
| Service Factor | 1.15 |
| Includes | Manual |
| Agency Compliance | c UL us |
| GPM of Water @ 25 Ft. of Head | 21 |
| Hz | 60 Hz |
| Screw Material | Stainless Steel |
| Application | Aggressive Liquid Applications, and Other General Purpose Pumping, Booster Service, Irrigation, Jockey Pump Service, Moderate Flow at Moderate Head Pressure, Spraying Systems, Transfer of Non-Flammable Liquids, Water Circulation |
| GPM of Water @ 60 Ft. of Head | 9 |
| GPM of Water @ 20 Ft. of Head | 23 |
| Motor Type | Not Applicable |
| Overall Length | 15.8 in |
| Overall Width | 7.6 in |
| Overall Height | 7-1/2 in |
| Standards | UL Recognized Motor |
| Ambient Temperature (Maximum) | 104 deg F |
| Shut Off Pressure (Maximum) | 68 ft of head |
| Flow Rate @ 40 ft of Head (Maximum) | 14 gpm |
| Flow Rate @ 25 ft of Head (Maximum) | 21 gpm |
| Best Efficiency Head | 35 ft |
| Cord Length | Not Applicable |
| Flow Rate @ 80 ft of Head (Maximum) | Not Applicable |
| Frequency | 60 Hz |
| Flow Rate @ 20 ft of Head (Maximum) | 23 gpm |
| Specific Gravity (Maximum) | 1 |
| Motor Speed (Maximum) | 3,450 rpm |
| Priming | Manual |
| Nameplate Voltage | 230/460V AC |
| Electrical Connection Type | Hardwired |
| Flow Rate @ 30 ft of Head (Maximum) | 19 gpm |
| Current | 1.7 to 1.6 or 0.8 A |
| Viscosity (Maximum) | 100 SUS |
| Best Efficiency Flow | 20 gpm |
| Horsepower (Maximum) | 0.5 HP |
| Media Temperature (Maximum) | 180 deg F |
| Discharge Rotation | None |
| Compatible Motor Frame | 56J NEMA |
| Discharge Pipe Size | 1-1/2 in |
| Case Pressure (Maximum) | 100 psi |
| Duty Cycle | Continuous |
| Flow Rate @ 70 ft of Head (Maximum) | Not Applicable |
| Media Temperature (Minimum) | Not Applicable |
| Solid Diameter (Maximum) | 1/4 in |
| Ambient Temperature (Minimum) | Not Applicable |
| Feet of Head (Maximum) | 68 ft |
| Flow Rate @ 10 ft of Head (Maximum) | 26 gpm |
| Intake Pipe Type | NPT |
| Flow Rate (Minimum) | 9 gpm |
| Flow Rate @ 15 ft of Head (Maximum) | 24 gpm |
| Flow Rate @ 60 ft of Head (Maximum) | Not Applicable |
| Flow Rate @ 5 ft of Head (Maximum) | Not Applicable |
| Flow Rate @ 1 ft of Head (Maximum) | Not Applicable |
| Shaft Outer Diameter | 5/8 in |
| For Use With Potable Systems | No |
| Intake Pipe Size | 1-1/2 in |
| Flow Rate (Maximum) | 26 gpm |
| Wetted Material | Carbon, Ceramic, Viton, Noryl |
| Impeller Design | Closed |
| Discharge Pipe Type | NPT |
| Impeller Diameter | 4-21/32 in |
| Flow Rate @ 260 ft of Head (Maximum) | Not Applicable |
| Discharge Rotation Increments | 0 deg |
| Flow Rate @ 90 ft of Head (Maximum) | Not Applicable |
| Motor Design | Three-Phase |
| Shaft Seal Type | Mechanical |
| Motor Speed - Maximum | 3,450 rpm |
| Flow Rate @ 180 ft of Head (Maximum) | Not Applicable |
| Ambient Temperature - Maximum | 104 deg F |
| Flow Rate @ 120 ft of Head (Maximum) | Not Applicable |
| Shut Off Pressure - Maximum | 29.4 psi |
| Shaft Seal Material | Ceramic, FKM, Carbon, Noryl |
| Feet of Head (Minimum) | 10 ft |
| Thermal Overload Protection | Yes |
| Number of Stages | 1 |
| Flow Rate @ 300 ft of Head (Maximum) | Not Applicable |
| Ambient Temperature - Minimum | Not Applicable |
| Inlet Diameter | 1-1/2 in |
| Suction Lift - Maximum | Not Applicable |
| Discharge Orientation | Top |
| Horsepower | 0.5 |
| Features | Not Applicable |
| Case Pressure - Maximum | 100 psi |
| Hazardous Location Class | Not Rated |
| Flow Rate @ 10 ft of Head - Maximum | 26 gpm |
| Full Load Current | 1.6/0.8 A |
| Motor Frame Size | 56J |
| Flow Rate @ 200 ft of Head (Maximum) | Not Applicable |
| Discharge Diameter | 1-1/2 in |
| Flow Rate @ 140 ft of Head (Maximum) | Not Applicable |
| Drive Coupling Type | No Coupling |
| Media Temperature - Minimum | 40 Degrees F |
| Flow Rate @ 160 ft of Head (Maximum) | Not Applicable |
| Inlet Orientation | Side |
| Mounting Orientation | Horizontal |
| Inlet Position | Center |
| Manufacturer Warranty Length | 1 yr |
| Flow Rate @ 50 ft of Head (Maximum) | 11 gpm |
| Discharge Position | Offset |
| Chemical Compatibility | Non-Flammable Liquids |
| Flow Rate @ 100 ft of Head (Maximum) | Not Applicable |
| Series | Not Applicable |
| Flow Rate @ 220 ft of Head (Maximum) | Not Applicable |
| Temperature Code | Not Applicable |
| Flow Rate @ 280 ft of Head (Maximum) | Not Applicable |
| Pumping Application | Booster Services, Irrigation, Jockey Pump Services, Spraying Systems, Water Circulation |
| Flow Rate @ 240 ft of Head (Maximum) | Not Applicable |
| Media Temperature - Maximum | 180 deg F |
| Pump Housing Material | Plastic |
| Wire Rope Length | 15.8 in |
| Fits Chest Size | Not Applicable |
| Country of Origin (subject to change) | India |
| Package Quantity | 1 |