The Eaton XT IEC contactor is a three-pole, non-reversing IEC magnetic contactor with a 1 NC auxiliary contact. It is operated by a 208 V AC, 60 Hz coil and uses screw terminals with DIN Rail or panel mounting. Voltage rating: rated for operation within the specified voltage range. Current rating: is rated for the specified current and load conditions (Inductive: 18 A; Resistive: 40 A). It is part of the XT series, frame size C.
Key features
| Item | IEC Magnetic Contactor |
|---|---|
| Auxiliary Contact Form | 1NC |
| Coil Voltage | 208V AC |
| Number of Poles | 3 |
| Full Load Amps-Inductive | 18 A |
| Full Load Amps-Resistive | 40 A |
| Reversing Capability | Non-Reversing |
| Terminal Connection Type | Screw |
| Number of Auxillary Contacts | 1 |
| Standards | CE, CSA, EN 60947, IEC 60947, RoHS, UL Listed |
| HP @ 3 Phase - 575V | 15 hp |
| Frame / Series / Class / Code | Frame C |
| HP @ 1 Phase - 230V | 3 |
| Reversing | No |
| Enclosure NEMA Rating | No Enclosure |
| Type | contactor |
| NEMA Size | Not Applicable |
| Series | XT |
| IP Rating | IP20 |
| Product Length/Depth | 3.425 in |
| Frame Size | C |
| Compliances | CE Marked |
| Contact Configuration | 1 NC |
| Amperage Rating | 18 A |
| Product Name | Eaton XT IEC contactor |
| Overall Depth | 3.43 in |
| Embedded Surge Suppressor | Yes |
| Mounting Hole Distance - Width | 1.38 in |
| Contactor Style | IEC |
| Full Load Current - Resistive | 40 A |
| Includes Auxiliary Contacts | Yes |
| Overall Width | 1.85 in |
| Overall Height | 3.9 in |
| Horsepower @ Three Phase - 600V AC | 15 HP |
| Mounting Style | DIN Rail, Panel |
| NEMA Enclosure Rating | No Enclosure |
| Minimum Operating Temperature | -13 deg F |
| Frequency | 60 Hz |
| Mounting Hole Diameter | 0.16 in |
| Maximum Operating Temperature | 122 deg F |
| Horsepower @ Three Phase - 208V AC | 5 HP |
| Mounting Hole Distance - Height | 2.95 in |
| Maximum Voltage Rating | 690V AC |
| Response Time | Less Than14 msec (AC Operated Opening Delay), Less Than22 msec (AC Operated Closing Delay), Less Than30 msec (DC Operated Opening Delay), Less Than47 msec (DC Operated Opening Delay) |
| Electrical Operating Durability | 2,000,000 |
| Horsepower @ Three Phase - 480V AC | 10 HP |
| NEMA Enclosure Material | Not Applicable |
| Mechanical Operating Durability | 10,000,000 |
| Horsepower @ Single Phase - 240V AC | 3 HP |
| Horsepower @ Three Phase - 240V AC | 5 HP |
| Phase | Three |
| Full Load Current - Inductive | 18 A |
| Horsepower @ Single Phase - 120V AC | 2 HP |
| Country of Origin (subject to change) | Romania |
| Package Quantity | 1 |