| Promotion Restriction | Not eligible for promotion |
|---|---|
| Item | Infrared Thermometer |
| Focus Spot Size and Distance - Infrared | 1 in a 30 in |
| Temp. Range (F) - Infrared | -58 to 1,832 deg F |
| Emissivity | Adjustable 0.10 to 1.00 |
| Temp. Accuracy (F) - Infrared | +/-4.5 Degrees |
| Temp. Accuracy (C) - Infrared | +/-2.5 Degrees |
| Laser Sighting | Convergence |
| Calibration Certificate Included | Yes |
| Data Logging - Instrument | No |
| Display - IR Camera | Backlit LCD |
| Accuracy | +/-1.0% |
| Response Time | 0.15 sec |
| Operating Temp. Range | 32 to 122 deg F |
| Trigger | Yes |
| Calibration Certificate | NIST |
| Manufacturers Warranty Length | 3 yr |
| Temperature Alarm - Thermometer | High, Low |
| Resolution | 0.1 Degrees F/C |
| Focus Spot Size and Distance | 1 in @ 12 in |
| Memory - Instrument | Max. |
| Temp. Range (C) | -50 to 1,000 deg C |
| Temp. Range (C) - Infrared | -50 to 1,000 deg C |
| Data Hold | Yes |
| Item - Infrared Thermometer | Infrared Thermometer |
| Spectral Response | 8 to 14 uM |
| Laser Sighting - Infrared | Convergence |
| Display | Backlit LCD |
| Special Features | At 30 in (76-1/2cm) Distance (2) Laser Points Converge to 1 in Target Spot |
| Battery Type | 9V |
| Includes | Carrying Case |
| Memory | Max |
| Repeatability | +/-0.5% or +/-1.8 Degrees F (1 Degrees C) |
| Spectral Response - Infrared | 8 to 14 um |
| Alarm Indication | Visual, Audible |
| Temp. Range (F) | -58 Degrees to 1,832 Degrees F |
| Alarm | High, Low |
| Temp. Range | -58 to 1,832 deg F |
| Standards | CE |
| Field of View | Not Applicable |
| Data Logging | No |
| Environmental Applications - Air Conditioners and Heat Pumps | Non-Medical |
| Features | Double Molded Housing, Lock Function for Continuous Readings |
| Auto Power Off | Yes |
| Type | Dual Laser |
| Laser Sighting Type | Dual |
| Interface | Not Applicable |
| Testing Functions | Maximum Temperature |
| Number of Batteries Required | 1 |
| Mounting Style | Handheld Only |
| Batteries Included | Yes |
| Maximum Temperature Measured Degrees F | 1,832 deg F |
| Maximum Emissivity Setting | 1.00 |
| Minimum Operating Temperature Degrees F | 32 deg F |
| Body Style | Full Size |
| Accuracy Degrees C | +/-1.0% of Reading or +/-1.0 Degrees Whichever is Greater |
| Maximum Operating Temperature Degrees F | 122 deg F |
| Temperature Alerts | High Temperature, Low Temperature |
| Battery Voltage | 9V |
| Includes Work Light | No Work Light Included |
| Maximum Temperature Measured Degrees C | 1,000 deg C |
| Digital Display Screen Type | LCD with Backlight |
| Minimum Emissivity Setting | 0.1 |
| Emissivity Adjustability | Adjustable |
| Battery Size | 9V |
| Resolution Degrees C | 0.1 deg C |
| Accuracy Degrees F | +/-1.0% of Reading or +2.0 Degrees Whichever is Greater |
| Secondary Measuring Method | No Secondary Measuring Method |
| Resolution Degrees F | 0.1 deg F |
| Alert Type | Sound |
| Distance To Spot Ratio | 30:1 |
| Calibration Certificate Type | NIST |
| Manufacturer Warranty Length | 3 yr |
| Intrinsic Safety | Not Specified Intrinsically Safe |
| Minimum Temperature Measured Degrees C | -50 deg C |
| Minimum Temperature Measured Degrees F | -58 deg F |
| Fits Chest Size | Double Molded Housing, Lock Function for Continuous Readings |
| Country of Origin (subject to change) | China |
| Package Quantity | 1 |