| Promotion Restriction | Not eligible for promotion |
|---|---|
| Item | Infrared Thermometer |
| Focus Spot Size and Distance - Infrared | 1 in @ 50 in |
| Temp. Range (F) - Infrared | -40 to 1,472 deg F |
| Emissivity | Adjustable 0.10 to 1.00 |
| Temp. Accuracy (F) - Infrared | +/-1.0% of Reading or +/-1.0 Degrees Whichever is Greater |
| Temp. Accuracy (C) - Infrared | +/-1.0% of Reading or +/-1.0 Degrees Whichever is Greater |
| Laser Sighting | Single Dot |
| Calibration Certificate Included | No |
| Data Logging - Instrument | Yes |
| Display - IR Camera | Dot Matrix LCD |
| Standards | ATEX/IECEx, GOST, INMETRO, NEC-500/NEC-505, PCEC |
| Response Time | 500 msec |
| Temp. Range (C) - Infrared | -40 to 800 deg C |
| Spectral Response | 8 to 14 uM |
| Operating Temp. Range | 32 to 122 deg F |
| Accuracy | +/-1.0 Degrees C or +/-1.0% |
| Includes | Hard Carrying Case, K Type Thermocouple Bead Probe |
| Special Features | Data Logs 99 Points |
| Data Hold | Yes |
| Alarm | High, Low |
| Display | Dot Matrix LCD |
| Calibration Certificate | No |
| Focus Spot Size and Distance | 1 in @ 50 in |
| Data Logging | Yes |
| Spectral Response - Infrared | 8 to 14 um |
| Memory | Max/Min/Avg/Dif |
| Temp. Range (C) | -40 to 800 deg C |
| Laser Sighting - Infrared | Single Dot |
| Alarm Indication | Visual, Audible |
| Item - Infrared Thermometer | Infrared Thermometer |
| Memory - Instrument | Avg., Dif., Max., Min |
| Repeatability | +/-0.5 Degrees C or +/-0.5% |
| Temp. Range (F) | -40 Degrees to 1,472 Degrees F |
| Trigger | Yes |
| Battery Type | AAA |
| Resolution | 0.1 Degrees F/C |
| Temperature Alarm - Thermometer | High, Low |
| Manufacturers Warranty Length | 2 yr |
| Field of View | Not Applicable |
| Environmental Applications - Air Conditioners and Heat Pumps | Non-Medical |
| Auto Power Off | Yes |
| Features | Comes with a Conductive Case to Safely Carry the IR Thermometer Into Hazardous Areas, Intrinsically Safe Infrared and Contact Thermometer, Meets Intrinsically Safe Certifications in Class I Div. 1 and Div. 2 or Zone 1 and 2 Hazardous Environments |
| Temperature Alerts | High Temperature, Low Temperature |
| Battery Run Time | 4 hr |
| Digital Display Screen Type | LCD |
| Testing Functions | Minimum Temperature |
| Resolution Degrees F | 0.1 deg F |
| Manufacturer Warranty Length | 2 yr |
| Calibration Certificate Type | Not Certified |
| Maximum Emissivity Setting | 1.00 |
| Maximum Temperature Measured Degrees F | 1,472 deg F |
| Laser Sighting Type | Single Dot |
| Includes Work Light | Work Light Included |
| Alert Type | Sound, Digital Display, Light |
| Number of Batteries Required | 2 |
| Resolution Degrees C | 0.1 deg C |
| Minimum Operating Temperature Degrees F | 32 deg F |
| Interface | USB |
| Mounting Style | Tripod |
| Accuracy Degrees C | +/-1.0% of Reading or +/-1.0 Degrees Whichever is Greater |
| Secondary Measuring Method | Type K Thermocouple |
| Emissivity Adjustability | Adjustable |
| Intrinsic Safety | Intrinsically Safe |
| Maximum Operating Temperature Degrees F | 122 deg F |
| Minimum Temperature Measured Degrees F | -40 deg F |
| Body Style | Compact |
| Minimum Emissivity Setting | 0.1 |
| Distance To Spot Ratio | 50:1 |
| Battery Size | AAA |
| Minimum Temperature Measured Degrees C | -40 deg C |
| Maximum Temperature Measured Degrees C | 800 deg C |
| Accuracy Degrees F | +/-1.0% of Reading or +/-2.0 Degrees Whichever is Greater |
| Fits Chest Size | Comes with a Conductive Case to Safely Carry the IR Thermometer Into Hazardous Areas, Intrinsically Safe Infrared and Contact Thermometer, Meets Intrinsically Safe Certifications in Class I Div. 1 and Div. 2 or Zone 1 and 2 Hazardous Environments |
| Country of Origin (subject to change) | China |
| Package Quantity | 1 |