| Promotion Restriction | Not eligible for promotion |
|---|---|
| Item | Insulation Tester |
| Standards | cCSAus, CE, N10140, TUV SUD |
| Calibration Certificate | Available Separately |
| Auto Power Off | Yes |
| Auto Ranging | Yes |
| Features | Calculates Prospective Earth Fault Current (PEFC/IK) and Prospective Short-Circuit Current (PSC/IK), Checks Wiring Polarity to Detect Broken N Wires, Includes Z-Max Memory for Loop Tests to Support Easy Evaluation of the Highest Loop Test Value, Measures Motor Windings with Continuity Test, Measures RCD Switching Time and Tripping Level (Ramp Test), Measures Trip Time and Current for RCD Type a and AC in One Test, Provides Automatic RCD Test Sequence, Provides Unique Zero Adapter for Fast, Reliable and Accurate Test Lead and Mains Cord Compensation |
| Includes | Hard Carrying Case, Mains Cord, Padded Carrying and Waist Strap, Quick Reference Guide, Standard Test Lead Set, TP165X Remote Control Probe and Lead, Zero Adapter |
| Tool Length | 3.9 in |
| Test Voltage | 100V DC, 1,000V DC, 250V DC, 500V DC |
| Insulation Limit Alarm | No |
| Insulation Resistance Resolution | 0.01 megaohm to 1 megaohm |
| Power Source | Leads |
| Data Logger | Yes |
| Manufacturer Warranty Length | 3 yr |
| Waterproof | No |
| Battery Size | AA |
| Test Current | 1 mA |
| Bluetooth Compatible | No |
| Minimum Insulation Resistance | 0.01 megaohm |
| Backlit Digital Display | Yes |
| PI/DAR Testing | No |
| Pass/Fail Selection Limits | No |
| IP Rating | IP40 |
| USB Data Download Included | Yes |
| Communication Protocol | USB |
| Capacitance Auto Discharge | Yes |
| Battery Chemistry | Alkaline |
| Maximum AC Voltage Measured | 500 V |
| Number of Records Stored | 3,000 |
| Alert Type | Digital Display |
| Number of Batteries Required | 6 |
| Display Type | Digital |
| Maximum Insulation Resistance | 1,000 megaohm |
| Greater Than 30V Warning | No |
| Timed Ramp Voltage Test | Yes |
| Parameters Measured | AC Voltage, Continuity, DC Voltage, Frequency, Ground Resistance |
| Number of Digits | 4 |
| CAT Safety Rating | CAT III, CAT IV 300V |
| Input Impedance | 360 kiloohm |
| Includes Batteries | Yes |
| Dustproof | No |
| Tool Width | 9.8 in |
| Resistance Accuracy | +/-5% |
| Live Circuit Voltage | 500V AC |
| Testing Functions | AC Voltage, Continuity, DC Voltage, Frequency, Insulation Resistance |
| Remote Test Probe Included | Yes |
| Tool Height | 4.9 in |
| Live Circuit Voltage Measurement - Minimum | 0 V AC |
| Maximum Ground Resistance Measurement | 2,000 ohm |
| Minimum AC Voltage Measured | 0 V |
| Installation Tester Socket Region | US |
| Leakage Current Range | Not Applicable |
| Instrument Style | Handheld |
| Live Circuit Voltage Measurement - Maximum | 500 V AC |
| Calibration Certificate Included | No Certification Included |
| Minimum Ground Resistance Measurement | 200 ohm |
| Data Output Type | USB |
| Display Screen Type | LCD Touchscreen |
| Power Source - TS Only | Leads |
| Power Source - old | Leads |
| Fits Chest Size | Calculates Prospective Earth Fault Current (PEFC/IK) and Prospective Short-Circuit Current (PSC/IK), Checks Wiring Polarity to Detect Broken N Wires, Includes Z-Max Memory for Loop Tests to Support Easy Evaluation of the Highest Loop Test Value, Measures Motor Windings with Continuity Test, Measures RCD Switching Time and Tripping Level (Ramp Test), Measures Trip Time and Current for RCD Type a and AC in One Test, Provides Automatic RCD Test Sequence, Provides Unique Zero Adapter for Fast, Reliable and Accurate Test Lead and Mains Cord Compensation |
| Country of Origin (subject to change) | United Kingdom |
| Package Quantity | 1 |