| Item | Indoor Air Quality Meter |
|---|---|
| Includes | (3) Adapters, EL-WEM WiFi Indoor Air Quality Monitor, Power Cable, PSU Power Supply |
| Features | Colored Status Ring Shows IAQ Level, Control Multiple Devices with EasyLog Cloud App, Uploads data to the EasyLog Cloud |
| Accuracy | +/- 0.6 mbar (Pressure), +/-0.6 Degrees C (Temperature, +/-3% (Humidity), +/-5% (Volatile Organic Compounds (VOC) |
| Temp. Range (F) | -676 to 2,028 |
| Sample Point Storage | Uploads Directly to The Cloud |
| Software Required | EasyLog Cloud App |
| Alarm | Audible |
| Time Intervals | 1 min |
| Digital Readout | Through Software |
| Special Features | Automatically Uploads Data to The EasyLog Cloud |
| Battery Life | Backup Battery 2-6 hr |
| Pressure Range | 300 to 1100 mbar |
| Relative Humidity Range | 0 to 95% |
| Temp. Range (C) | -20 to 60 deg C |
| Type | Humidity, Particulate Matter, Pressure, Temperature, Volatile Organic Compounds |
| Dia. | 77 mm |
| Voltage Range | 5V DC |
| Calibration Certificate | CE, UK CA |
| DC Voltage Accuracy | Not Applicable |
| Maximum Pressure Measured | 1,100 mbar |
| Maximum Relative Humidity Measured | 95 % |
| AC Current Accuracy | Not Applicable |
| Minimum Relative Humidity Measured | 0 % |
| Minimum Temperature Measured Degrees F | Not Applicable |
| Battery Run Time | 6 hr |
| Maximum Temperature Measured Degrees C | 60 deg C |
| Overall Diameter | 77 mm |
| AC Voltage Accuracy | Not Applicable |
| Maximum DC Current Measurement | Not Applicable |
| Minimum DC Current Measurement | Not Applicable |
| DC Current Accuracy | Not Applicable |
| Parameters Measured | Pressure, Relative Humidity, Temperature Degrees C |
| Current Channels | Not Applicable |
| Maximum DC Voltage Measured | Not Applicable |
| Maximum AC Voltage Measured | Not Applicable |
| Minimum Dew Point Measured | Not Applicable |
| Minimum AC Voltage Measured | Not Applicable |
| Number of Voltage Channels | Not Applicable |
| Software Options | Software Available Separately |
| Power Source | Battery |
| Battery Voltage | 5V |
| Minimum AC Current Measurement | Not Applicable |
| Maximum Dew Point Measured | Not Applicable |
| Minimum DC Voltage Measured | Not Applicable |
| Minimum Temperature Measured Degrees C | -20 deg C |
| Accuracy Degrees C | +/-0.6 deg C |
| Alert Type | Sound |
| Maximum AC Current Measurement | Not Applicable |
| Maximum Temperature Measured Degrees F | Not Applicable |
| Power Source - TS Only | Battery |
| Power Source - old | Battery |
| Fits Chest Size | Colored Status Ring Shows IAQ Level, Control Multiple Devices with EasyLog Cloud App, Uploads data to the EasyLog Cloud |
| Country of Origin (subject to change) | China |
| Package Quantity | 1 |