Product Description
The NVENT SES40120/240 is a service entrance suppressor for electrical system protection. This device features a compact NEMA-4 enclosure, making it suitable for flush mounting in various spaces. It operates efficiently at 120/240 VAC, ideal for typical power distribution systems in residential and small commercial environments.
Protects service entrance and distribution panels.
LED indicator displays operational status.
Maximum surge rating of 40 kA 8/20 µs.
Product Highlights
Designed for efficient surge protection, this suppressor is specifically engineered for service entrance applications.
Product Information
Standard Information
Brand: NVENT
MPN: SES40120/240
Technical Specifications
Nominal System Voltage (Un): 120/240 V
Distribution System: 1Ph 3W+G
Maximum Continuous Operating Voltage (Uc): 170/276 VAC
Frequency: 50 - 60 Hz
Short Circuit Current Rating (SCCR): 200 kA
Nominal Discharge Current (In): 20 kA 8/20 µs
Maximum Discharge Current (Imax), Per Mode: 40 kA 8/20 µs
Voltage Protection Rating (VPR): 800 V @ 3 kA; 1200 V @ 20 kA
Protection Modes: L-L; L-N; L-PE
Status Indication: LED
Technology: MOV with thermal disconnect
Lead Length: 30
Lead Size: #10
Ground Lead Length: 36
Operating Temperature: -40 to 176 °F
Enclosure Material: Metal
Enclosure Rating: IP 65; NEMA-4
Mounting Type: 3/4 straight nipple
Depth: 2.87
Height: 3.27
Width: 3.27
Unit Weight: 1.54 lb
Certifications: UL 1449 Edition 5 Type 1/2, 20 kA Mode
Complies With: ANSI/IEEE C62.41.2-2002 Cat A, Cat B, Cat C; ANSI/IEEE C62.41.2-2002 Scenario II, Exposure 2, 20 kA 8/20 µs, 2 kA 10/350 µs; IEC 61643-1 Class II
Product DescriptionThe NVENT SES40120/240 is a service entrance suppressor for electrical system protection. This device features a compact NEMA-4 enclosure, making it suitable for flush mounting in various spaces. It operates efficiently at 120/240 VAC, ideal for typical power distribution systems in residential and small commercial environments.
Protects service entrance and distribution panels.
LED indicator displays operational status.
Maximum surge rating of 40 kA 8/20 µs.
Product HighlightsDesigned for efficient surge protection, this suppressor is specifically engineered for service entrance applications.Product InformationStandard Information
Brand: NVENT
MPN: SES40120/240
Technical Specifications
Nominal System Voltage (Un): 120/240 V
Distribution System: 1Ph 3W+G
Maximum Continuous Operating Voltage (Uc): 170/276 VAC
Frequency: 50 - 60 Hz
Short Circuit Current Rating (SCCR): 200 kA
Nominal Discharge Current (In): 20 kA 8/20 µs
Maximum Discharge Current (Imax), Per Mode: 40 kA 8/20 µs
Voltage Protection Rating (VPR): 800 V @ 3 kA; 1200 V @ 20 kA
Protection Modes: L-L; L-N; L-PE
Status Indication: LED
Technology: MOV with thermal disconnect
Lead Length: 30
Lead Size: #10
Ground Lead Length: 36
Operating Temperature: -40 to 176 °F
Enclosure Material: Metal
Enclosure Rating: IP 65; NEMA-4
Mounting Type: 3/4 straight nipple
Depth: 2.87
Height: 3.27
Width: 3.27
Unit Weight: 1.54 lb
Certifications: UL 1449 Edition 5 Type 1/2, 20 kA Mode
Complies With: ANSI/IEEE C62.41.2-2002 Cat A, Cat B, Cat C; ANSI/IEEE C62.41.2-2002 Scenario II, Exposure 2, 20 kA 8/20 µs, 2 kA 10/350 µs; IEC 61643-1 Class II
Vendor: NVENT
Vendor Raw: NVENT
Product Type: DISCONNECTS
Availability Text: In Stock
Brand: NVENT
MPN: SES40120/240
Nominal System Voltage (Un): 120/240 V
Distribution System: 1Ph 3W+G
Maximum Continuous Operating Voltage (Uc): 170/276 VAC
Frequency: 50 - 60 Hz
Short Circuit Current Rating (SCCR): 200 kA
Nominal Discharge Current (In): 20 kA 8/20 µs
Maximum Discharge Current (Imax), Per Mode: 40 kA 8/20 µs
Voltage Protection Rating (VPR): 800 V @ 3 kA; 1200 V @ 20 kA
Protection Modes: L-L; L-N; L-PE
Status Indication: LED
Technology: MOV with thermal disconnect
Lead Length: 30
Lead Size: #10
Ground Lead Length: 36
Operating Temperature: -40 to 176 °F
Enclosure Material: Metal
Enclosure Rating: IP 65; NEMA-4
Mounting Type: 3/4 straight nipple
Depth: 2.87
Height: 3.27
Width: 3.27
Unit Weight: 1.54 lb
Certifications: UL 1449 Edition 5 Type 1/2, 20 kA Mode
Complies With: ANSI/IEEE C62.41.2-2002 Cat A, Cat B, Cat C; ANSI/IEEE C62.41.2-2002 Scenario II, Exposure 2, 20 kA 8/20 µs, 2 kA 10/350 µs; IEC 61643-1 Class II
Tags: AI_Content, loc_2, Parcel
Source file: SES40120-240 - nvent-ses40120-240-service-entrance-suppressor.json.json
| Brand | NVENT |
|---|---|
| MPN | SES40120/240 |
| Nominal System Voltage (Un) | 120/240 V |
| Distribution System | 1Ph 3W+G |
| Maximum Continuous Operating Voltage (Uc) | 170/276 VAC |
| Frequency | 50 - 60 Hz |
| Short Circuit Current Rating (SCCR) | 200 kA |
| Nominal Discharge Current (In) | 20 kA 8/20 µs |
| Maximum Discharge Current (Imax), Per Mode | 40 kA 8/20 µs |
| Voltage Protection Rating (VPR) | 800 V @ 3 kA; 1200 V @ 20 kA |
| Protection Modes | L-L; L-N; L-PE |
| Status Indication | LED |
| Technology | MOV with thermal disconnect |
| Lead Length | 30 |
| Lead Size | #10 |
| Ground Lead Length | 36 |
| Operating Temperature | -40 to 176 °F |
| Enclosure Material | Metal |
| Enclosure Rating | IP 65; NEMA-4 |
| Mounting Type | 3/4 straight nipple |
| Depth | 2.87 |
| Height | 3.27 |
| Width | 3.27 |
| Unit Weight | 1.54 lb |
| Certifications | UL 1449 Edition 5 Type 1/2, 20 kA Mode |
| Complies With | ANSI/IEEE C62.41.2-2002 Cat A, Cat B, Cat C; ANSI/IEEE C62.41.2-2002 Scenario II, Exposure 2, 20 kA 8/20 µs, 2 kA 10/350 µs; IEC 61643-1 Class II |
| Vendor | NVENT |
| Vendor Raw | NVENT |
| SKU | SES40120/240 |
| Tipo de producto | DISCONNECTS |
| Disponibilidad | In Stock |
| Mensaje de envío | Ships Same Day if Ordered by 12 pm |
| Moneda | USD |
| Handle Shopify | nvent-ses40120-240-service-entrance-suppressor |
| Shopify Product ID | 9931002806578 |
| Peso | 1.54 lb |
| Peso gramos | 699 |
| Tags | AI_Content, loc_2, Parcel |